Literature DB >> 18299071

Modified cow-hitch suture fixation of transscleral sutured posterior chamber intraocular lenses: long-term safety and efficacy.

Simon X Chen1, Lawrence R Lee, Freda Sii, Adrian Rowley.   

Abstract

PURPOSE: To evaluate the long-term safety and efficacy of a new technique using a modified cow-hitch knot for transscleral suture fixation of posterior chamber intraocular lenses (PC IOLs).
SETTING: Public hospital in Brisbane, Australia.
METHODS: A retrospective chart review was conducted of consecutive patients who had transscleral sutured PC IOL implantation from March 2000 to June 2006 using the new technique, which was modified to eliminate free suture ends and minimize the risk for knot slippage. Data collected included demographic data, ocular history, preoperative and final best corrected visual acuities (BCVAs), preoperative and postoperative intraocular pressure (IOP), and postoperative complications.
RESULTS: Eighty-two eyes of 79 patients (51 men, 28 women) with a mean age of 62.5 years+/-18.9 (SD) were included in the study. The mean follow-up was 22.9+/-21.2 months (range 5 to 76 months). The BCVA was 20/40 or better in 45 eyes (54.9%) and 20/200 or worse in 10 eyes (12.2%). The final BCVA was largely determined by the preoperative underlying ocular pathology. Postoperative complications included temporary increased IOP in 14 eyes (17.1%), escalated glaucoma in 7 eyes (8.5%), temporary hypotony in 7 eyes (8.5%), and retinal detachment, hyphema, and irregular astigmatism in 1 eye (1.2%) each. The PC IOLs remained well centered and without tilt in all eyes.
CONCLUSIONS: The technique provided excellent PC IOL centration in the presence of no adequate capsule support. It was effective and safe for transscleral suturing of PC IOLs.

Entities:  

Mesh:

Year:  2008        PMID: 18299071     DOI: 10.1016/j.jcrs.2007.10.034

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  8 in total

1.  A safe method of ciliary sulcus fixation of foldable intraocular lens using a ciliary sulcus guide.

Authors:  Ertuğrul Can; Adem Gül; Hakkı Birinci
Journal:  Int Ophthalmol       Date:  2015-10-06       Impact factor: 2.031

2.  Late dislocation of the capsular bag-intraocular lens-modified capsular tension ring complex after knotless transscleral suturing using 9-0 polypropylene.

Authors:  Natalia S Anisimova; Lisa B Arbisser; Natalya F Shilova; Roman V Kirtaev; Daria A Dibina; Boris E Malyugin
Journal:  Digit J Ophthalmol       Date:  2020-06-26

3.  Modified technique for transscleral fixation of posterior chamber intraocular lenses.

Authors:  Chongde Long; Yantao Wei; Zhaohui Yuan; Zhiqing Zhang; Xiaofeng Lin; Bingqian Liu
Journal:  BMC Ophthalmol       Date:  2015-10-02       Impact factor: 2.209

4.  Three cases of a torn haptic after scleral fixation using a hydrophobic acrylic intraocular lens: Case reports.

Authors:  Min-Ji Kang; Choun-Ki Joo
Journal:  Medicine (Baltimore)       Date:  2018-02       Impact factor: 1.889

5.  Clinical observation of a novel technique: transscleral suture fixation of a foldable 3-looped haptics one-piece posterior chamber intraocular lens implantation through scleral pockets with intact conjunctiva.

Authors:  Shuang Ni; Wei Wang; Xiang Chen; Xingdi Wu; Suhong He; Yajuan Ma; Wen Xu
Journal:  BMC Ophthalmol       Date:  2019-05-09       Impact factor: 2.209

6.  Modified Technique for Scleral-Sutured Fixation with the Double Knots Technique for Posterior Chamber Intraocular Lens: Short-Term Observation.

Authors:  Zhizhong Wu; Caijuan Liu; Yanhui Xu; Wei Dong; Zhimin Chen
Journal:  J Ophthalmol       Date:  2021-02-27       Impact factor: 1.909

7.  Intraocular lens implantation in the absence of capsular support.

Authors:  Nicholas T Gurney; Zaina Al-Mohtaseb
Journal:  Saudi J Ophthalmol       Date:  2022-08-29

8.  One-Haptic Fixation of Posterior Chamber Intraocular Lenses without Scleral Flaps.

Authors:  Ashraf I Moawad; Asaad A Ghanem
Journal:  J Ophthalmol       Date:  2012-08-05       Impact factor: 1.909

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.