LED vs halogen light-curing of adhesive-precoated brackets.

Davide Mirabella1, Raffaele Spena, Giovanni Scognamiglio, Lombardo Luca, Antonio Gracco, Giuseppe Siciliani.   

Abstract

OBJECTIVE: To test the hypothesis that bonding with a blue light-emitting diode (LED) curing unit produces no more failures in adhesive-precoated (APC) orthodontic brackets than bonding carried out by a conventional halogen lamp.
MATERIALS AND METHODS: Sixty-five patients were selected for this randomized clinical trial, in which a total of 1152 stainless steel APC brackets were employed. In order to carry out a valid comparison of the bracket failure rate following use of each type of curing unit, each patient's mouth was divided into four quadrants. In 34 of the randomly selected patients, designated group A, the APC brackets of the right maxillary and left mandibular quadrants were bonded using a halogen light, while the remaining quadrants were treated with an LED curing unit. In the other 31 patients, designated group B, halogen light was used to cure the left maxillary and right mandibular quadrants, whereas the APC brackets in the remaining quadrants were bonded using an LED dental curing light. The bonding date, the type of light used for curing, and the date of any bracket failures over a mean period of 8.9 months were recorded for each bracket and, subsequently, the chi-square test, the Yates-corrected chi-square test, the Fisher exact test, Kaplan-Meier survival estimates, and the log-rank test were employed in statistical analyses of the results.
RESULTS: No statistically significant difference in bond failure rate was found between APC brackets bonded with the halogen light-curing unit and those cured with LED light. However, significantly fewer bonding failures were noted in the maxillary arch (1.67%) than in the mandibular arch (4.35%) after each light-curing technique.
CONCLUSIONS: The hypothesis cannot be rejected since use of an LED curing unit produces similar APC bracket failure rates to use of conventional halogen light, with the advantage of a far shorter curing time (10 seconds).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18298197     DOI: 10.2319/042707-211.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  6 in total

1.  Does a reduction of polymerization time and bonding steps affect the bond strength of brackets?

Authors:  Timea Lamper; Stefanie Steinhäuser-Andresen; Karin C Huth; Nicoleta Ilie; Ekaterini Paschos
Journal:  Clin Oral Investig       Date:  2011-03-30       Impact factor: 3.573

2.  Clinical long-term success of contemporary nano-filled resin composites in class I and II restorations cured by LED or halogen light.

Authors:  Torsten Pflaum; Stefan Kranz; Regina Montag; Arndt Güntsch; Andrea Völpel; Robin Mills; Klaus Jandt; Bernd Sigusch
Journal:  Clin Oral Investig       Date:  2017-10-28       Impact factor: 3.573

3.  Clinical effect of reducing curing times with high-intensity LED lights.

Authors:  Justin D Ward; Bethany J Wolf; Luis P Leite; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

4.  Factors influencing treatment efficiency.

Authors:  Min-Ho Jung
Journal:  Angle Orthod       Date:  2021-01-01       Impact factor: 2.079

5.  A 15-month evaluation of bond failures of orthodontic brackets bonded with direct versus indirect bonding technique: a clinical trial.

Authors:  Anna Menini; Mauro Cozzani; Maria Francesca Sfondrini; Andrea Scribante; Paolo Cozzani; Paola Gandini
Journal:  Prog Orthod       Date:  2014-12-30       Impact factor: 2.750

6.  Survival analysis of brackets and tubes: A twelve-month assessment.

Authors:  Min-Ho Jung
Journal:  Angle Orthod       Date:  2014-03-25       Impact factor: 2.079

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.