Topographic changes after hyperopic LASIK with the SCHWIND ESIRIS laser platform.

Diego de Ortueta1, Samuel Arba-Mosquera, Holger Baatz.   

Abstract

PURPOSE: To analyze and compare refractive power changes with topographic changes after hyperopic LASIK using the ESIRIS laser platform.
METHODS: Sixty-six consecutive eyes of 37 patients were evaluated retrospectively. Outcomes were evaluated at 3 months. In all cases, standard examinations including pre- and postoperative topographic and corneal wavefront analysis with a Keratron topographer were performed. Preoperative mean spherical equivalent was +/- 2.74 diopters (D) with a mean cylinder of 0.67 D. The ESIRIS excimer laser system was used to perform ablations. Topographic changes of Maloney index, simulated keratometry (sim-K), and K-reading at 5 and 7 mm were evaluated.
RESULTS: Ninety-two percent of eyes were within +/- 0.50 D manifest refraction at 3 months postoperatively. Changes in refraction, Maloney indices, and sim-K indices after surgery were strongly correlated with the intended correction. Induction of negative corneal spherical aberrations and increased prolate asphericity was correlated with the achieved defocus correction. No other Zernike mode was significantly correlated. Topographically, an overcorrection within the central 3 mm and a gradual peripheral undercorrection also was observed.
CONCLUSIONS: Analyzing the topographic maps, the corneal power change of the Maloney indices correlated with the intended correction. After hyperopic LASIK, an overcorrection was observed in the 3-mm central zone, and progressive undercorrections were observed in the 5- and 7-mm zones.

Entities:  

Mesh:

Year:  2008        PMID: 18297937     DOI: 10.3928/1081597X-20080201-03

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  4 in total

1.  Pilot study of hyperopic LASIK using the solid-state laser technology.

Authors:  David P Piñero; Francisco J Blanes-Mompó; Pedro Ruiz-Fortes; Rafael J Pérez-Cambrodí; Antonio Alzamora-Rodríguez
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-05       Impact factor: 3.117

2.  No change in anterior chamber dimensions after femtosecond LASIK for hyperopia.

Authors:  Xiaodong Zhou; Tao Li; Zhi Chen; Lingling Niu; Xingtao Zhou; Zimei Zhou
Journal:  Eye Contact Lens       Date:  2015-05       Impact factor: 2.018

3.  Corneal power changes with Scheimpflug rotating camera after hyperopic LASIK.

Authors:  Woong-Joo Whang; Young-Sik Yoo; Choun-Ki Joo
Journal:  Medicine (Baltimore)       Date:  2018-12       Impact factor: 1.817

4.  Scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction.

Authors:  Dan Fu; Jianmin Shang; Xiaoyu Zhang; Lingling Niu; Tian Han; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2021-07-20       Impact factor: 2.209