Literature DB >> 18297493

Subject-specific non-linear biomechanical model of needle insertion into brain.

A Wittek1, T Dutta-Roy, Z Taylor, A Horton, T Washio, K Chinzei, K Miller.   

Abstract

The previous models for predicting the forces acting on a needle during insertion into very soft organs (such as, e.g. brain) relied on oversimplifying assumptions of linear elasticity and specific experimentally derived functions for determining needle-tissue interactions. In this contribution, we propose a more general approach in which the needle forces are determined directly from the equations of continuum mechanics using fully non-linear finite element procedures that account for large deformations (geometric non-linearity) and non-linear stress-strain relationship (material non-linearity) of soft tissues. We applied these procedures to model needle insertion into a swine brain using the constitutive properties determined from the experiments on tissue samples obtained from the same brain (i.e. the subject-specific constitutive properties were used). We focused on the insertion phase preceding puncture of the brain meninges and obtained a very accurate prediction of the needle force. This demonstrates the utility of non-linear finite element procedures in patient-specific modelling of needle insertion into soft organs such as, e.g. brain.

Entities:  

Mesh:

Year:  2008        PMID: 18297493     DOI: 10.1080/10255840802296665

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  5 in total

1.  Development of in vivo constitutive models for liver: application to surgical simulation.

Authors:  Kevin Lister; Zhan Gao; Jaydev P Desai
Journal:  Ann Biomed Eng       Date:  2010-12-16       Impact factor: 3.934

2.  Suite of meshless algorithms for accurate computation of soft tissue deformation for surgical simulation.

Authors:  Grand Joldes; George Bourantas; Benjamin Zwick; Habib Chowdhury; Adam Wittek; Sudip Agrawal; Konstantinos Mountris; Damon Hyde; Simon K Warfield; Karol Miller
Journal:  Med Image Anal       Date:  2019-06-12       Impact factor: 8.545

Review 3.  Current progress in patient-specific modeling.

Authors:  Maxwell Lewis Neal; Roy Kerckhoffs
Journal:  Brief Bioinform       Date:  2009-12-02       Impact factor: 11.622

4.  Long-term changes in the material properties of brain tissue at the implant-tissue interface.

Authors:  Arati Sridharan; Subramaniam D Rajan; Jit Muthuswamy
Journal:  J Neural Eng       Date:  2013-10-08       Impact factor: 5.379

5.  Mathematical modeling and computer simulation of needle insertion into soft tissue.

Authors:  Adam Wittek; George Bourantas; Benjamin F Zwick; Grand Joldes; Lionel Esteban; Karol Miller
Journal:  PLoS One       Date:  2020-12-22       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.