Clinical outcome of adjuvant treatment of endometrial cancer using aperture-based intensity-modulated radiotherapy.

Myriam Bouchard1, Sylvain Nadeau, Luc Gingras, Paul-Emile Raymond, Frédéric Beaulieu, Luc Beaulieu, André Fortin, Isabelle Germain.   

Abstract

PURPOSE: To assess disease control and acute and chronic toxicity with aperture-based intensity-modulated radiotherapy (AB-IMRT) for postoperative pelvic irradiation of endometrial cancer. METHODS AND MATERIALS: Between January and July 2005, after hysterectomy for endometrial cancer, 15 patients received 45 Gy to the pelvis using AB-IMRT. The AB-IMRT plans were generated by an in-house treatment planning system (Ballista). The AB-IMRT plans were used for treatment and were dosimetrically compared with three other approaches: conventional four-field, enlarged four-field, and beamlet-based IMRT (BB-IMRT). Disease control and toxicity were prospectively recorded and compared with retrospective data from 30 patients treated with a conventional four-field technique.
RESULTS: At a median follow-up of 27 months (range, 23-30), no relapse was noted among the AB-IMRT group compared with five relapses in the control group (p = 0.1). The characteristics of each group were similar, except for the mean body mass index, timing of brachytherapy, and applicator type used. Patients treated with AB-IMRT experienced more frequent Grade 2 or greater gastrointestinal acute toxicity (87% vs. 53%, p = 0.02). No statistically significant difference was noted between the two groups regarding the incidence or severity of chronic toxicities. AB-IMRT plans significantly improved target coverage (93% vs. 76% of planning target volume receiving 45 Gy for AB-IMRT vs. conventional four-field technique, respectively). The sparing of organs at risk was similar to that of BB-IMRT.
CONCLUSION: The results of our study have shown that AB-IMRT provides excellent disease control with equivalent late toxicity compared with the conventional four-field technique. AB-IMRT provided treatment delivery and quality assurance advantages compared with BB-IMRT and could reduce the risk of second malignancy compared with BB-IMRT.

Entities:  

Mesh:

Year:  2008        PMID: 18294780     DOI: 10.1016/j.ijrobp.2007.12.004

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  6 in total

1.  Para-aortic and pelvic extended-field radiotherapy for advanced-stage uterine cancer: dosimetric and toxicity comparison between the four-field box and intensity-modulated techniques.

Authors:  A Rabinovich; L Bernard; A V Ramanakumar; G Stroian; W H Gotlieb; S Lau; B Bahoric
Journal:  Curr Oncol       Date:  2015-12       Impact factor: 3.677

2.  Intensity-modulated radiotherapy in patients with cervical cancer. An intra-individual comparison of prone and supine positioning.

Authors:  Carmen Stromberger; Yves Kom; Michael Kawgan-Kagan; Tristan Mensing; Ulrich Jahn; Achim Schneider; Volker Budach; Christhardt Köhler; Simone Marnitz
Journal:  Radiat Oncol       Date:  2010-07-02       Impact factor: 3.481

3.  Safety of adjuvant intensity-modulated postoperative radiation therapy in endometrial cancer: Clinical data and dosimetric parameters according to the International Commission on Radiation Units (ICRU) 83 report.

Authors:  Abel Cordoba; Philippe Nickers; Emmanuelle Tresch; Bernard Castelain; Eric Leblanc; Fabrice Narducci; Florence Le Tinier; Anne Lesoin; Thomas Lacornerie; Eric Lartigau
Journal:  Rep Pract Oncol Radiother       Date:  2015-07-03

4.  Helical tomotherapy provides efficacy similar to that of intensity-modulated radiation therapy with dosimetric benefits for endometrial carcinoma.

Authors:  Chen-Hsi Hsieh; Pei-Wei Shueng; Sheng-Mou Hsiao; Ming-Chow Wei; Wen-Yih Wu; Hsu-Dong Sun; Hui-Ju Tien; Li-Ying Wang; Yen-Ping Hsieh
Journal:  Onco Targets Ther       Date:  2012-10-01       Impact factor: 4.147

5.  Optimization of photon beam energy in aperture-based inverse planning.

Authors:  Jason St-Hilaire; Caroline Sévigny; Frédéric Beaulieu; Luc Gingras; Daniel Tremblay; Luc Beaulieu
Journal:  J Appl Clin Med Phys       Date:  2009-09-03       Impact factor: 2.102

6.  Optimization of re-irradiation using deformable registration: a case study.

Authors:  Raphaël Jumeau; Nicolas Péguret; Cédric Zulliger; Raphaël Moeckli; Jean Bourhis; Esat-Mahmut Ozsahin
Journal:  BJR Case Rep       Date:  2016-05-06