Literature DB >> 18294476

Rationale and design of the Home Automatic External Defibrillator Trial (HAT).

Gust H Bardy1, Kerry L Lee, Daniel B Mark, Jeanne E Poole, William D Toff, Andrew M Tonkin, Warren Smith, Paul Dorian, Julie J Yallop, Douglas L Packer, Roger D White, Will Longstreth, Jill Anderson, George Johnson, Eric Bischoff, Crystal D Munkers, Amanda Brown, Steven McNulty, Linda Davidson Ray, Nancy E Clapp-Channing, Yves Rosenberg, Marcel Salive, Eleanor B Schron.   

Abstract

Most cardiac arrests occur in the home, where emergency medical services (EMS) systems are challenged to provide timely care. Because a large proportion of sudden cardiac arrests (SCAs) are due to ventricular tachycardia or ventricular fibrillation, home use of an automated external defibrillator (AED) might offer an opportunity to decrease mortality in those at risk. Predicting who will have a cardiac arrest in the general population is difficult. Individuals at high risk are usually easily identified and may become candidates for implantable cardioverter defibrillators. It is within the population at lower risk where home AEDs may be most useful. The purpose of the Home Automatic External Defibrillator Trial (HAT) is to test whether providing home access to an AED can improve survival in patients at modest risk of SCA, such as those surviving an anterior myocardial infarction but in whom implantable cardioverter defibrillator therapy is not deemed necessary. Between January 23, 2003, and October 20, 2005, 7001 patients were enrolled, with completion of follow-up scheduled for September 30, 2007. Randomization was conducted in a 1:1 fashion between control therapy, comprising the standard lay response to SCA (calling the EMS and performing cardiopulmonary resuscitation), and the use of an AED first, followed by calling the EMS and performing cardiopulmonary resuscitation. The primary end point is all-cause mortality. Secondary outcomes include survival from SCA (witnessed and unwitnessed, in home and out of home), incremental cost-effectiveness, and quality of life measures for both the patient and the spouse/companion. The results of the trial should be available in mid 2008.

Entities:  

Mesh:

Year:  2008        PMID: 18294476     DOI: 10.1016/j.ahj.2007.12.008

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  4 in total

1.  Quality of life effects of automatic external defibrillators in the home: results from the Home Automatic External Defibrillator Trial (HAT).

Authors:  Daniel B Mark; Kevin J Anstrom; Steven E McNulty; Greg C Flaker; Andrew M Tonkin; Warren M Smith; William D Toff; Paul Dorian; Nancy E Clapp-Channing; Jill Anderson; George Johnson; Eleanor B Schron; Jeanne E Poole; Kerry L Lee; Gust H Bardy
Journal:  Am Heart J       Date:  2010-04       Impact factor: 4.749

2.  Pets, depression and long term survival in community living patients following myocardial infarction.

Authors:  Erika Friedmann; Sue A Thomas; Heesook Son
Journal:  Anthrozoos       Date:  2011-09-01       Impact factor: 1.689

3.  Changes in anxiety and depression over 2 years in medically stable patients after myocardial infarction and their spouses in the Home Automatic External Defibrillator Trial (HAT): a longitudinal observational study.

Authors:  Sue A Thomas; Erika Friedmann; Hyeon-Joo Lee; Heesook Son; Patricia G Morton
Journal:  Heart       Date:  2010-10-07       Impact factor: 5.994

4.  Weighing the benefits and burdens of witnessed resuscitation.

Authors:  Daniel B Kramer; Susan L Mitchell
Journal:  N Engl J Med       Date:  2013-03-14       Impact factor: 91.245

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.