Literature DB >> 18292443

Cervical spine motion during tracheal intubation with manual in-line stabilization: direct laryngoscopy versus GlideScope videolaryngoscopy.

Arnaud Robitaille1, Stephan R Williams, Marie-Hélène Tremblay, François Guilbert, Mélanie Thériault, Pierre Drolet.   

Abstract

BACKGROUND: The optimal tracheal intubation technique for patients with potential cervical (C) spine injury remains controversial. Using continuous cinefluoroscopy, we conducted a prospective study comparing C-spine movement during intubation using direct laryngoscopy (DL) or GlideScope videolaryngoscopy (GVL), with uninterrupted manual in-line stabilization of the head by an assistant.
METHODS: Twenty patients without C-spine pathology were studied. After induction of general anesthesia with neuromuscular blockade, both DL and GVL were performed on every patient in random order. Cinefluoroscopic images of C-spine movement during GVL and DL were acquired and divided into four stages: a baseline image before airway manipulation, glottic visualization, insertion of the endotracheal tube into the glottis, and tracheal intubation. Peak segmental motion from the occiput to C5 was measured offline for each patient and each stage, averages were calculated, and movements induced by each instrument were compared using a two-way ANOVA. Also studied were the proportion of patients with occiput-C1 rotation exceeding 10, 15, or 20 degrees, and the quality of glottic visualization.
RESULTS: No significant difference was found between DL and GVL regarding average segmental spine movement at any level (P values between 0.22 and 0.70). During both techniques, motion was mainly an extension concentrated in the rostral C-spine and occurred predominantly during glottic visualization. The proportion of patients with occiput-C1 extension of more than 10, 15, or 20 degrees was not significantly different. Glottic visualization was significantly better with GVL compared with DL.
CONCLUSION: During intubation under general anesthesia with neuromuscular blockade and manual in-line stabilization, the use of GVL produced better glottic visualization, but did not significantly decrease movement of the nonpathologic C-spine when compared with DL.

Entities:  

Mesh:

Year:  2008        PMID: 18292443     DOI: 10.1213/ane.0b013e318161769e

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  30 in total

Review 1.  [Awake fiberoptic intubation].

Authors:  F Gerheuser; K Gürtler
Journal:  Anaesthesist       Date:  2011-12       Impact factor: 1.041

Review 2.  [Indirect laryngoscopy : Alternatives to securing the airway].

Authors:  R R Noppens; C Werner; T Piepho
Journal:  Anaesthesist       Date:  2010-02       Impact factor: 1.041

3.  Emergency Neurological Life Support: Airway, Ventilation, and Sedation.

Authors:  Venkatakrishna Rajajee; Becky Riggs; David B Seder
Journal:  Neurocrit Care       Date:  2017-09       Impact factor: 3.210

4.  Distortion of anterior airway anatomy during laryngoscopy with the GlideScope videolaryngoscope.

Authors:  Yoshihiro Hirabayashi; Akifumi Fujita; Norimasa Seo; Hideharu Sugimoto
Journal:  J Anesth       Date:  2010-04-06       Impact factor: 2.078

5.  The pressure exerted on the tongue during intubation with simultaneous cervical spine immobilisation: a comparison between four videolaryngoscopes and the Macintosh laryngoscope-a manikin study.

Authors:  Dawid Aleksandrowicz; Tomasz Gaszyński
Journal:  J Clin Monit Comput       Date:  2017-12-20       Impact factor: 2.502

6.  Advances in laryngoscopy: rigid indirect laryngoscopy.

Authors:  Deanne R Cheyne; Patrick Doyle
Journal:  F1000 Med Rep       Date:  2010-08-19

7.  A comparison of 4 airway devices on cervical spine alignment in cadaver models of global ligamentous instability at c1-2.

Authors:  Adam L Wendling; Patrick J Tighe; Bryan P Conrad; Tezcan Ozrazgat Baslanti; Marybeth Horodyski; Glenn R Rechtine
Journal:  Anesth Analg       Date:  2013-01-25       Impact factor: 5.108

Review 8.  Traumatic brain injury: A case-based review.

Authors:  Liza Victoria S Escobedo; Joseph Habboushe; Haytham Kaafarani; George Velmahos; Kaushal Shah; Jarone Lee
Journal:  World J Emerg Med       Date:  2013

9.  A comparison of the C-MAC video laryngoscope to the Macintosh direct laryngoscope for intubation in the emergency department.

Authors:  John C Sakles; Jarrod Mosier; Stephen Chiu; Mari Cosentino; Leah Kalin
Journal:  Ann Emerg Med       Date:  2012-05-05       Impact factor: 5.721

10.  Maxillofacial trauma patient: coping with the difficult airway.

Authors:  Amir A Krausz; Imad Abu El-Naaj; Michal Barak
Journal:  World J Emerg Surg       Date:  2009-05-27       Impact factor: 5.469

View more