Literature DB >> 18291932

Optimal space-varying regularization in iterative image restoration.

S J Reeves1.   

Abstract

It has been shown that space-variant regularization in image restoration provides better results than space-invariant regularization. However, the optimal choice of the regularization parameter is usually unknown a priori. In previous work, the generalized cross-validation (GCV) criterion was shown to provide accurate estimates of the optimal regularization parameter. The author introduces a modified form of the GCV criterion that incorporates space-variant regularization and data error terms. Furthermore, he presents an efficient method for estimating the GCV criterion for the space-variant case using iterative image restoration techniques. This method performs nearly as well as the exact criterion for the image restoration problem. In addition, he proposes a Wiener filter interpretation for choosing the local weighting of the regularization. This interpretation suggests the use of a multistage estimation procedure to estimate the optimal choice of the local regularization weights. Experiments confirm the value of the modified GCV estimation criterion as well as the multistage procedure for estimating the local regularization weights.

Entities:  

Year:  1994        PMID: 18291932     DOI: 10.1109/83.287028

Source DB:  PubMed          Journal:  IEEE Trans Image Process        ISSN: 1057-7149            Impact factor:   10.856


  4 in total

1.  Enhancing precision in time-domain fluorescence lifetime imaging.

Authors:  Ching-Wei Chang; Mary-Ann Mycek
Journal:  J Biomed Opt       Date:  2010 Sep-Oct       Impact factor: 3.170

2.  Regularization parameter selection for nonlinear iterative image restoration and MRI reconstruction using GCV and SURE-based methods.

Authors:  Sathish Ramani; Zhihao Liu; Jeffrey Rosen; Jon-Fredrik Nielsen; Jeffrey A Fessler
Journal:  IEEE Trans Image Process       Date:  2012-04-17       Impact factor: 10.856

3.  Distinct effects of attention on the neural responses to form and motion processing: a SSVEP source-imaging study.

Authors:  Melanie Palomares; Justin M Ales; Alex R Wade; Benoit R Cottereau; Anthony M Norcia
Journal:  J Vis       Date:  2012-09-26       Impact factor: 2.240

Review 4.  How to use fMRI functional localizers to improve EEG/MEG source estimation.

Authors:  Benoit R Cottereau; Justin M Ales; Anthony M Norcia
Journal:  J Neurosci Methods       Date:  2014-08-01       Impact factor: 2.390

  4 in total