Literature DB >> 18291186

Comparison of mini-cardiopulmonary bypass system with air-purge device to conventional bypass system.

Lian K Ti1, Bok-Lan Goh, Poo-Sing Wong, Patsy Ong, Si-Guim Goh, Chuen-Neng Lee.   

Abstract

BACKGROUND: Although mini-cardiopulmonary bypass systems reduce inflammation, hemodilution, and transfusion requirements, the problem of air entrainment and embolization into the system has limited its use. Newer systems incorporate an air purge to address this problem. We compared the benefits and possible risks in using the newer mini-cardiopulmonary bypass system with those for conventional cardiopulmonary bypass.
METHODS: Data of 60 patients who underwent cardiac surgery with a newer mini-cardiopulmonary bypass system incorporating an air purge from August 2005 to July 2006 (group A) were retrospectively collected and compared with that of 60 matched patients who underwent cardiac surgery with conventional cardiopulmonary bypass during the same period (group B). Matching criteria were prebypass hematocrit, body surface area, age, and surgical procedure.
RESULTS: Demographic and background data were similar for both groups. There were no detectable episodes of air embolism. Patients in group A had higher initial and nadir hematocrits during cardiopulmonary bypass and received fewer transfusions. However, postoperative blood loss and transfusion requirements were similar in both groups. Episodes of low indexed flows during cardiopulmonary bypass commonly occurred in group A, and this was associated with a greater than 50% decrease in urine output and lower mixed venous oxygen saturations (58% +/- 6% versus 68% +/- 5%) as compared with group B. There were no differences in clinical outcomes.
CONCLUSIONS: The newer mini-cardiopulmonary bypass system addressed the problem of air embolization. It preserved hematocrit and reduced transfusion during cardiopulmonary bypass, but did not improve outcomes postoperatively. It is unclear whether these benefits outweigh the potential risk of hypoperfusion associated with its use.

Entities:  

Mesh:

Year:  2008        PMID: 18291186     DOI: 10.1016/j.athoracsur.2007.09.001

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

Review 1.  [Cardiopulmonary bypass in cardiac surgery].

Authors:  T Baehner; O Boehm; C Probst; B Poetzsch; A Hoeft; G Baumgarten; P Knuefermann
Journal:  Anaesthesist       Date:  2012-10       Impact factor: 1.041

2.  Oxygen delivery during cardiopulmonary bypass (and renal outcome) using two systems of extracorporeal circulation: a retrospective review.

Authors:  Mark J Bennett; Cha Rajakaruna; Samer Bazerbashi; Gerry Webb; Mayam Gomez-Cano; Clinton Lloyd
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-02-20

3.  Miniaturized cardiopulmonary bypass: the Hammersmith technique.

Authors:  Aziz Momin; Mansour Sharabiani; John Mulholland; Gemma Yarham; Barnaby Reeves; Jon Anderson; Gianni Angelini
Journal:  J Cardiothorac Surg       Date:  2013-06-03       Impact factor: 1.637

  3 in total