Literature DB >> 18291178

Hypothermic circulatory arrest: safety and efficacy in the operative treatment of descending and thoracoabdominal aortic aneurysms.

Joseph S Coselli1, Jovan Bozinovski, Catherine Cheung.   

Abstract

BACKGROUND: The safety and efficacy of hypothermic circulatory arrest in the operative treatment of descending thoracic aortic aneurysms and thoracoabdominal aortic aneurysms are not clearly established. We evaluated our experience with repair of descending thoracic and thoracoabdominal aortic aneurysms using hypothermic circulatory arrest.
METHODS: In all, 111 patients with descending thoracic aortic aneurysms (83) or thoracoabdominal aortic aneurysms (28) underwent graft replacement of the involved aortic segments using hypothermic circulatory arrest. The technique was used when the location, extent, and severity of disease precluded placement of a proximal aortic clamp. Mean patient age was 61.4 +/- 13.1 years and 81 (73%) were male. Nine patients (8%) presented with acute dissection; 74 (67%) had chronic dissection; 56 patients (51%) required emergency operations, including 16 (14%) with ruptured aneurysms. Mean circulatory arrest time was 39.7 +/- 16.2 minutes.
RESULTS: There were no intraoperative deaths. There were 31 operative deaths (28%), including 23 patients (21%) who died within 30 days. Operative mortality was 29% (30 of 102) for patients undergoing emergent or urgent operations and 1% (1 of 9) for all elective cases (p = 0.4). Postoperative paraplegia developed in 1 patient (1%) and 17 patients (15%) had postoperative renal failure. Cardiac complications occurred in 26 patients (23%), reoperation for bleeding in 6 (5%), tracheostomy was required in 24 (22%), and 10 (9%) sustained postoperative stroke.
CONCLUSIONS: When cross clamping the aorta is not feasible, hypothermic circulatory arrest can be performed but with an increased morbidity and mortality rate.

Entities:  

Mesh:

Year:  2008        PMID: 18291178     DOI: 10.1016/j.athoracsur.2007.11.014

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  7 in total

Review 1.  Current strategies for spinal cord protection during thoracic and thoracoabdominal aortic aneurysm repair.

Authors:  Hideyuki Shimizu; Ryohei Yozu
Journal:  Gen Thorac Cardiovasc Surg       Date:  2011-03-30

2.  Open thoracoabdominal aortic aneurysm repair in expert hands: "all roads lead to Rome".

Authors:  Giacomo Murana; Jacopo Alfonsi; Luca Di Marco; Davide Pacini
Journal:  Ann Transl Med       Date:  2017-10

Review 3.  Spinal cord injury as a complication of thoracic endovascular aneurysm repair.

Authors:  Taijiro Sueda; Shinya Takahashi
Journal:  Surg Today       Date:  2017-09-18       Impact factor: 2.549

4.  Cohort comparison of thoracic endovascular aortic repair with open thoracic aortic repair using modern end-organ preservation strategies.

Authors:  Dean J Arnaoutakis; George J Arnaoutakis; Christopher J Abularrage; Robert J Beaulieu; Ashish S Shah; Duke E Cameron; James H Black
Journal:  Ann Vasc Surg       Date:  2015-03-07       Impact factor: 1.466

5.  Recent outcomes of surgery for chronic type B aortic dissection.

Authors:  Yasushi Takagi; Motomi Ando; Yoshiro Higuchi; Kiyotoshi Akita; Masato Tochii; Michiko Ishida; Kan Kaneko; Ryo Hoshino; Masato Sato
Journal:  Ann Vasc Dis       Date:  2010-12-02

6.  Endovascular repair for a descending thoracic aortic aneurysm with a stent-graft covering the celiac artery: report of two cases.

Authors:  Hiroyuki Ishibashi; Tsuneo Ishiguchi; Takashi Ohta; Ikuo Sugimoto; Jun Kawanishi; Tetsuya Yamada; Noriyuki Hida; Seiji Kamei
Journal:  Surg Today       Date:  2009-05-27       Impact factor: 2.549

7.  Long-term outcomes of intervention between open repair and endovascular aortic repair for descending aortic pathologies: a propensity-matched analysis.

Authors:  Shin-Ah Son; Hanna Jung; Joon Yong Cho
Journal:  BMC Surg       Date:  2020-11-03       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.