Handling of inhaler devices in actual pulmonary practice: metered-dose inhaler versus dry powder inhalers.

Basheer Y Khassawneh1, Musa K Al-Ali, Karem H Alzoubi, Morad Z Batarseh, Saafan A Al-Safi, Abdelmonem M Sharara, Hatem M Alnasr.   

Abstract

BACKGROUND: Handling of inhaler devices such as pressurized metered-dose inhalers (MDIs) and dry-powder inhalers (DPIs) in actual pulmonary practice is not well studied.
OBJECTIVE: The aim of this study was to evaluate patients' proper handling of inhaler devices during actual pulmonary practice.
METHODS: Prospective observational evaluations were conducted at 3 pulmonary clinics in Jordan, from February 2006 until August 2006. MDI (without spacer), Turbuhaler, Diskus, and Aerolizer devices were studied. Incorrect handling was defined as improper technique in any of the predefined essential steps.
RESULTS: Patients (n = 300) were recruited and 525 inhaler-device handling technique evaluations were completed. Diskus inhaler had the lowest rate of incorrect handling (7/103, 6.8%) and MDI had the highest rate of incorrect handling (144/193, 74.6%). Turbuhaler and Aerolizer were handled incorrectly by 63/146 (43.2%) and 14/83 (16.9%) patients, respectively. DPI had a lower rate of incorrect handling, when compared with the MDI (p < 0.001). Among the DPI devices, the Diskus had the lowest rate of incorrect handling (p < 0.031).
CONCLUSIONS: In actual pulmonary clinical practice the majority of patients were unable to use MDI correctly, whereas correct handling of DPI devices was variable. Regular checking of inhalation technique and proper teaching by health care providers is crucial for optimum use of most inhaler devices.

Entities:  

Mesh:

Year:  2008        PMID: 18291048

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  28 in total

1.  Inhalation devices and patient interface: human factors.

Authors:  Stefan Leiner; David Parkins; Orest Lastow
Journal:  AAPS J       Date:  2015-01-16       Impact factor: 4.009

2.  Personalization of Device Therapy - Prime Time for Peak Inspiratory Flow Rate.

Authors:  Chee H Loh; Jill A Ohar
Journal:  Chronic Obstr Pulm Dis       Date:  2017-07-14

3.  The effect of using simulation for training pharmacy students on correct device technique.

Authors:  Iman A Basheti
Journal:  Am J Pharm Educ       Date:  2014-12-15       Impact factor: 2.047

4.  Controller Inhalers: Overview of Devices, Instructions for Use, Errors, and Interventions to Improve Technique.

Authors:  Patrick K Gleeson; Scott Feldman; Andrea J Apter
Journal:  J Allergy Clin Immunol Pract       Date:  2020-03-12

5.  Teach-Back Experience and Hospitalization Risk Among Patients with Ambulatory Care Sensitive Conditions: a Matched Cohort Study.

Authors:  Young-Rock Hong; Michelle Cardel; Ryan Suk; Ivana A Vaughn; Ashish A Deshmukh; Carla L Fisher; Gregory Pavela; Kalyani Sonawane
Journal:  J Gen Intern Med       Date:  2019-08-05       Impact factor: 5.128

6.  Safety and efficacy of fluticasone propionate/salmeterol hydrofluoroalkane 134a metered-dose-inhaler compared with fluticasone propionate/salmeterol diskus in patients with chronic obstructive pulmonary disease.

Authors:  Andras Koser; Jan Westerman; Sanjay Sharma; Amanda Emmett; Glenn D Crater
Journal:  Open Respir Med J       Date:  2010-10-21

7.  Are Sudanese community pharmacists capable to prescribe and demonstrate asthma inhaler devices to patrons? A mystery patient study.

Authors:  Abuzar Osman; Imad S Ahmed Hassan; Mohamed Izham M Ibrahim
Journal:  Pharm Pract (Granada)       Date:  2012-06-30

8.  From inhaler to lung: clinical implications of the formulations of ciclesonide and other inhaled corticosteroids.

Authors:  Ruediger Nave; Helgert Mueller
Journal:  Int J Gen Med       Date:  2013-03-07

9.  The importance of inhaler devices: the choice of inhaler device may lead to suboptimal adherence in COPD patients.

Authors:  Josep Darbà; Gabriela Ramírez; Antoni Sicras; Pablo Francoli; Saku Torvinen; Rainel Sánchez-de la Rosa
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2015-10-29

10.  Assessment of metered-dose inhaler technique: A study at the pulmonology clinic of a tertiary hospital in the Free State, South Africa.

Authors:  Y Ramkillawan; M Prins; C van van Rooyen; R Y Seedat
Journal:  Afr J Thorac Crit Care Med       Date:  2019-04-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.