Literature DB >> 18290881

Sixteen-slice multidetector computed tomography for graft patency evaluation after coronary artery bypass surgery.

Miguel Sousa Uva1, Fernando Matias, Armindo Mesquita, Rogério Costa, José Baú, Albino Pedro, Manuel Pedro Magalhães.   

Abstract

OBJECTIVE: To investigate the ability of 16-slice multidetector computed tomography (MDCT) to assess coronary artery bypass graft patency and to detect bypass stenosis by comparison with coronary angiography.
METHODS: Thirty patients underwent both conventional coronary bypass angiography and retrospective ECG gated 16-slice multidetector computed tomography after surgery using 0.4 seconds rotation time and 1.25 mm slice thickness.
RESULTS: Among a total of 107 bypass grafts, 101 grafts (94.4%) were evaluable by MDCT. Thirteen patients were taking oral beta blockers. Mean heart rate was 73.6 (52-105). Of the 40 internal mammary arteries and two radial arteries examined, only one was occluded by coronary bypass angiography and MDCT, resulting in a sensitivity of 100% and a specificity of 100%. MDCT correctly diagnosed all patent venous grafts and missed two of the 14 venous grafts shown occluded by conventional angiography resulting in a sensitivity of 85.7% and specificity of 100%. When occluded grafts were excluded, MDCT did not detect two out of two anastomotic arterial graft stenosis >50% and resulted in one false positive result for a sensitivity and specificity of 0% and 97.4%, respectively. MDCT correctly diagnosed one out of three venous stenosis >50% and falsely diagnosed one venous graft stenosis >50% yielding a 33.3% and 97.6% sensitivity and specificity, respectively.
CONCLUSION: Sixteen-slice MDCT allows for noninvasive evaluation of coronary bypass grafts patency with high diagnostic accuracy. Assessment of distal anastomotic stenosis was deficient, particularly for arterial grafts, still limited by low resolution or artifacts. Improved accuracy may be obtained by more aggressive heart rate reduction.

Entities:  

Mesh:

Year:  2008        PMID: 18290881     DOI: 10.1111/j.1540-8191.2007.00479.x

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  4 in total

1.  64-slice multidetector computed tomographic evaluation of arterial conduit patency after off-pump coronary artery bypass grafting.

Authors:  Vito A Mannacio; Massimo Imbriaco; Severino Iesu; Agostino LaMarca Giordano; Luigi Di Tommaso; Carlo Vosa
Journal:  Tex Heart Inst J       Date:  2009

2.  Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography.

Authors:  Hosseinali Bassri; Farzad Salari; Fereidoun Noohi; Marzieh Motevali; Seifollah Abdi; Nader Givtaj; Kamal Raissi; Majid Haghjoo
Journal:  BMC Cardiovasc Disord       Date:  2009-12-08       Impact factor: 2.298

Review 3.  Postmortem imaging of sudden cardiac death.

Authors:  Katarzyna Michaud; Silke Grabherr; Christian Jackowski; Marc Daniel Bollmann; Franceso Doenz; Patrice Mangin
Journal:  Int J Legal Med       Date:  2013-01-16       Impact factor: 2.686

4.  Rationale, design and methodology for a Prospective Randomized Study of graft patency in Off-pump and On-pump MultI-vessel coronary artery bypasS Surgery (PROMISS) using multidetector computed tomography.

Authors:  Miguel Sousa Uva; Fernando Matias; Sara Cavaco; Manuel Pedro Magalhães
Journal:  Trials       Date:  2008-07-17       Impact factor: 2.279

  4 in total