Literature DB >> 18287878

Drug release kinetics from stent device-based delivery systems.

Belay Tesfamariam1.   

Abstract

In an effort to overcome the limitations of balloon-expandible intravascular metal stent-induced neointimal formation, drug-coated stent devices have been developed. The stent platform allows the local delivery of drugs to an injury site, thereby reducing the amount of drug exposure to the systemic circulation and other organs. The drug carrier matrix allows the release of the drug in a diffusion-controlled manner over an extended time period after the stent implant. The drugs are chosen such that the complex cascade of events that occurs after stent implantation that leads to smooth muscle cell proliferation and migration towards the intima are inhibited. The success of an antirestenotic drug therapy from a drug-coated stent is dependent, at least partially, on the extent of drug elution from the stent, the duration and rate of release, and accumulation of drug in the arterial wall in such a way that it covers the initiation and progression of vessel wall remodeling. The local vascular drug concentrations achieved are directly correlated with the biological effects and local vascular toxicity, and there is therefore a challenge in finding an optimum dose of drug to be delivered to tissues (ie, one that has the desired therapeutic effect without local adverse effects). There is increased focus on optimization of various factors that affect drug release from the stent system, including the physicochemical properties of the drugs, carrier vehicle formulation, and profile of elution kinetics. This review highlights the various factors involved in drug release kinetics, local vascular toxicity, carrier vehicle matrix, tissue deposition, and distribution through the arterial wall from stent-based drug delivery systems.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18287878     DOI: 10.1097/FJC.0b013e318158540f

Source DB:  PubMed          Journal:  J Cardiovasc Pharmacol        ISSN: 0160-2446            Impact factor:   3.105


  6 in total

Review 1.  Endothelial Repair and Regeneration Following Intimal Injury.

Authors:  Belay Tesfamariam
Journal:  J Cardiovasc Transl Res       Date:  2016-01-21       Impact factor: 4.132

Review 2.  Vascular inflammation and repair: implications for re-endothelialization, restenosis, and stent thrombosis.

Authors:  Teruo Inoue; Kevin Croce; Toshifumi Morooka; Masashi Sakuma; Koichi Node; Daniel I Simon
Journal:  JACC Cardiovasc Interv       Date:  2011-10       Impact factor: 11.195

3.  Estimation of drug-polymer miscibility and solubility in amorphous solid dispersions using experimentally determined interaction parameters.

Authors:  Patrick J Marsac; Tonglei Li; Lynne S Taylor
Journal:  Pharm Res       Date:  2008-09-09       Impact factor: 4.200

4.  Optimization of Drug Delivery by Drug-Eluting Stents.

Authors:  Franz Bozsak; David Gonzalez-Rodriguez; Zachary Sternberger; Paul Belitz; Thomas Bewley; Jean-Marc Chomaz; Abdul I Barakat
Journal:  PLoS One       Date:  2015-06-17       Impact factor: 3.240

5.  Safety and efficacy of a novel iopromide-based paclitaxel-eluting balloon following bare metal stent implantation in rabbit aorta abdominalis.

Authors:  Zhengbin Zhu; Hui Han; Jinzhou Zhu; Jing Zhang; Run Du; Jingwei Ni; Chen Ying; Xuanqi An; Ruiyan Zhang
Journal:  Biomed Mater Eng       Date:  2015       Impact factor: 1.300

Review 6.  Recent advance in treatment of atherosclerosis: Key targets and plaque-positioned delivery strategies.

Authors:  Li Li; Sainan Liu; Jianying Tan; Lai Wei; Dimeng Wu; Shuai Gao; Yajun Weng; Junying Chen
Journal:  J Tissue Eng       Date:  2022-03-24       Impact factor: 7.813

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.