Sonography of the teres minor: a study of cadavers.

Hyun-Min Kim1, Nirvikar Dahiya, Sharlene A Teefey, Jay D Keener, Ken Yamaguchi.   

Abstract

OBJECTIVE: The purpose of our study was to evaluate in cadavers the ability of high-resolution sonography to identify both the normal tendinous insertion and tears of the teres minor.
MATERIALS AND METHODS: The teres minor insertion in five cadaveric shoulders was imaged, and methylene blue dye was injected into both the superior and inferior margins of the teres minor insertion by experienced musculoskeletal radiologists using a 10-5-MHz linear array transducer. Afterward, posterior shoulder dissection was performed. In another group of 11 cadaveric shoulders, an artificial tear was created at the teres minor insertion in six shoulders, and a sham procedure was performed in the remaining five shoulders arthroscopically. After arthroscopy, the teres minor insertion of each shoulder was imaged, and the accuracy of sonography for detecting a tear was evaluated.
RESULTS: The dye was injected correctly into both the superior and inferior margins of the teres minor insertion in all five cadaveric shoulders. All six artificial tears were successfully detected on sonography. Four of the five specimens with the sham procedure were identified as having a normal teres minor insertion. One was misinterpreted as a tear.
CONCLUSION: Sonography can reliably be used to identify the teres minor insertion and to detect tears of the teres minor muscle-tendon unit.

Entities:  

Mesh:

Year:  2008        PMID: 18287426     DOI: 10.2214/AJR.07.2960

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  The teres minor muscle in rotator cuff tendon tears.

Authors:  Barbara Melis; Michael J DeFranco; Alexandre Lädermann; Renaud Barthelemy; Gilles Walch
Journal:  Skeletal Radiol       Date:  2011-05-24       Impact factor: 2.199

Review 2.  Comprehensive Shoulder US Examination: A Standardized Approach with Multimodality Correlation for Common Shoulder Disease.

Authors:  Matthew H Lee; Scott E Sheehan; John F Orwin; Kenneth S Lee
Journal:  Radiographics       Date:  2016-10       Impact factor: 5.333

3.  Diagnostic performance and reliability of ultrasonography for fatty degeneration of the rotator cuff muscles.

Authors:  Lindley B Wall; Sharlene A Teefey; William D Middleton; Nirvikar Dahiya; Karen Steger-May; H Mike Kim; Daniel Wessell; Ken Yamaguchi
Journal:  J Bone Joint Surg Am       Date:  2012-06-20       Impact factor: 5.284

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.