Literature DB >> 18286617

Genotoxicity and cytotoxicity in multiple organs induced by titanium miniplates in Wistar rats.

Rodrigo Piozzi1, Daniel Araki Ribeiro, Luís Eduardo Marques Padovan, Hugo Nary Filho, Mariza Akemi Matsumoto.   

Abstract

Internal fixture materials are currently used as metallic biomaterials in rehabilitation of human body. Nevertheless, metal release due to corrosion phenomena appears to play a crucial role for human health. Thus, the goal of the present study was to evaluate whether liver, kidney, and lung are particularly sensitive organs for DNA damaging and cytotoxicity following implantation of internal fixture materials composed by titanium alloy in vivo. A total of 18 rats underwent surgical titanium miniplates in their tibias, being randomly distributed into three groups: 30 days, 90 days, and 180 days after implantation. A total of six animals served as negative control (animals that not received any implant). After experimental design, the lung, liver, and kidney were removed for histopatological and genotoxic analysis as depicted by H.E. stain and single cell gel (comet) assay, respectively. No significant statistically differences (p > 0.05) for DNA damaging were found to all experimental groups when compared to negative control for all organs evaluated. In addition, no remarkable morphological alterations were detected under histopathological analysis. Taken together, such results suggest that titanium miniplates are neither able to induce DNA damage in multiple organs nor to cause some abnormalities in lung, liver, and kidney.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 18286617     DOI: 10.1002/jbm.a.31876

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  3 in total

1.  Metallic ion content and damage to the DNA in oral mucosa cells patients treated dental implants.

Authors:  Pía López-Jornet; Francisco Parra Perrez; José Luis Calvo-Guirado; Irene Ros-Llor; Irene LLor-Ros; Piedad Ramírez-Fernández
Journal:  J Mater Sci Mater Med       Date:  2014-03-29       Impact factor: 3.896

2.  Metal release and corrosion effects of modular neck total hip arthroplasty.

Authors:  J Philippe Kretzer; Eike Jakubowitz; Michael Krachler; Marc Thomsen; Christian Heisel
Journal:  Int Orthop       Date:  2009-02-14       Impact factor: 3.075

3.  Biological Safety Evaluation and Surface Modification of Biocompatible Ti-15Zr-4Nb Alloy.

Authors:  Yoshimitsu Okazaki; Shin-Ichi Katsuda
Journal:  Materials (Basel)       Date:  2021-02-04       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.