Literature DB >> 18285008

Quantitative real-time imaging of myocardium based on ultrasonic integrated backscatter.

L J Thomas1, B Barzilai, J E Perez, B E Sobel, S A Wickline, J G Miller.   

Abstract

The integrated backscatter calculation over the full, two-dimensional echocardiographic sector is implemented to produce images from closed-chest dogs. This new real-time integrated backscatter measurement system allows a continuous determination of integrated backscatter from all myocardial regions in the ultrasonic view. By replacing the conventional video processor in a commercial two-dimensional echocardiographic imager with this new real-time backscatter measurement system, it is possible to produce real-time two-dimensional images based on integrated backscatter.

Entities:  

Year:  1989        PMID: 18285008     DOI: 10.1109/58.31785

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  7 in total

1.  Novel ultrasonic fusion imaging method based on cyclic variation in myocardial backscatter.

Authors:  J Bai; Y Jiang; X Li; D Pan; G Hu; P He
Journal:  Med Biol Eng Comput       Date:  2002-03       Impact factor: 2.602

2.  Microfluidic droplet sorting with a high frequency ultrasound beam.

Authors:  Changyang Lee; Jungwoo Lee; Hyung Ham Kim; Shia-Yen Teh; Abraham Lee; In-Young Chung; Jae Yeong Park; K Kirk Shung
Journal:  Lab Chip       Date:  2012-05-29       Impact factor: 6.799

Review 3.  Ultrasound Imaging Techniques for Spatiotemporal Characterization of Composition, Microstructure, and Mechanical Properties in Tissue Engineering.

Authors:  Cheri X Deng; Xiaowei Hong; Jan P Stegemann
Journal:  Tissue Eng Part B Rev       Date:  2016-03-14       Impact factor: 6.389

4.  Analysis of Two Quantitative Ultrasound Approaches.

Authors:  Pauline Muleki-Seya; Aiguo Han; Michael P Andre; John W Erdman; William D O'Brien
Journal:  Ultrason Imaging       Date:  2017-09-25       Impact factor: 1.578

5.  Spatial Angular Compounding Technique for H-Scan Ultrasound Imaging.

Authors:  Mawia Khairalseed; Fangyuan Xiong; Jung-Whan Kim; Robert F Mattrey; Kevin J Parker; Kenneth Hoyt
Journal:  Ultrasound Med Biol       Date:  2017-10-12       Impact factor: 2.998

6.  Layer-dependent variation in the anisotropy of apparent integrated backscatter from human coronary arteries.

Authors:  Joseph J Hoffman; Benjamin L Johnson; Mark R Holland; Russell J Fedewa; Anuja Nair; James G Miller
Journal:  Ultrasound Med Biol       Date:  2011-03-03       Impact factor: 2.998

7.  Backscattering measurement from a single microdroplet.

Authors:  Jungwoo Lee; Jin Ho Chang; Jong Seob Jeong; Changyang Lee; Shia-Yen Teh; Abraham Lee; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-04       Impact factor: 2.725

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.