Physical image quality comparison of four types of digital detector for chest radiology.

J M Fernandez1, J M Ordiales, E Guibelalde, C Prieto, E Vano.   

Abstract

Image quality for similar exposure conditions has been compared for two computed radiography (CR) systems (needle-based and conventional storage phosphor) and two flat-panel (DR) systems from different manufacturers mainly devoted to chest radiology. Image quality was assessed with a contrast-detail object and acrylic material to simulate clinical conditions. Specific image evaluation software was used to measure the contrast and obtain an image quality figure. Phantom and detector incident air kerma were measured for all images. Image quality differences were significant, and in the range of 100-300 microGy (phantom incident air kerma) the needle-based CR system and one of the DR systems show similar image quality and they are quite superior when compared with the conventional CR system.

Entities:  

Mesh:

Year:  2008        PMID: 18283060     DOI: 10.1093/rpd/ncn026

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  7 in total

1.  Assessment of patient doses in CR examinations throughout a large health region.

Authors:  Yogesh Thakur; Thorarin A Bjarnason; Kevin Hammerstrom; Lorie Marchinkow; Tim Koch; John E Aldrich
Journal:  J Digit Imaging       Date:  2012-02       Impact factor: 4.056

2.  Optimization of Image Quality and Dose in Digital Mammography.

Authors:  Agnes M F Fausto; M C Lopes; M C de Sousa; Tânia A C Furquim; Anderson W Mol; Fermin G Velasco
Journal:  J Digit Imaging       Date:  2017-04       Impact factor: 4.056

3.  Optimisation of radiological protocols for chest imaging using computed radiography and flat-panel X-ray detectors.

Authors:  G Compagnone; M Casadio Baleni; E Di Nicola; M Valentino; M Benati; L F Calzolaio; N Oberhofer; E Fabbri; S Domenichelli; L Barozzi
Journal:  Radiol Med       Date:  2012-10-22       Impact factor: 3.469

4.  Visual grading analysis of digital neonatal chest phantom X-ray images: Impact of detector type, dose and image processing on image quality.

Authors:  M H Smet; L Breysem; E Mussen; H Bosmans; N W Marshall; L Cockmartin
Journal:  Eur Radiol       Date:  2018-02-19       Impact factor: 5.315

5.  Intramodality and intermodality comparisons of storage phosphor computed radiography and conventional film-screen radiography in the recognition of small pneumoconiotic opacities.

Authors:  A Scott Laney; Edward L Petsonk; Michael D Attfield
Journal:  Chest       Date:  2011-05-26       Impact factor: 9.410

Review 6.  Storage Phosphors for Medical Imaging.

Authors:  Paul Leblans; Dirk Vandenbroucke; Peter Willems
Journal:  Materials (Basel)       Date:  2011-06-09       Impact factor: 3.623

7.  Needle-based storage-phosphor detector radiography is superior to a conventional powder-based storage phosphor detector and a high-resolution screen-film system in small patients (budgerigars and mice).

Authors:  Wiebke Tebrün; Eberhard Ludewig; Claudia Köhler; Julia Böhme; Michael Pees
Journal:  Sci Rep       Date:  2019-07-11       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.