Literature DB >> 1828091

The safety of intraaortic balloon pump catheter insertion through suprainguinal prosthetic vascular bypass grafts.

G M LaMuraglia1, G J Vlahakes, A C Moncure, D C Brewster, M J Buckley, W M Daggett, I Palacios, R Cambria, C W Akins, D F Torchiana.   

Abstract

To determine the safety of intraaortic balloon pump catheter insertion for critical coronary ischemia through suprainguinal prosthetic bypass grafts, we examined our experience of 19 intraaortic balloon pumps placed through grafts in 17 patients by means of surgical exposure (8) or the percutaneous (11) approach. Fourteen intraaortic balloon pumps were placed through matured grafts at a time remote (2 to 13 years; mean, 7 years) from their vascular bypass surgery. Five were inserted through nonmatured grafts during the same hospitalization as their vascular reconstructive surgery (1 to 12 days; mean, 4 days). One patient, a day after an aortoiliac bypass, died during an urgent, surgical intraaortic balloon pump insertion for cardiogenic shock. All other patients had prompt reversal of their cardiac ischemia. Decreased limb perfusion developed during use of the intraaortic balloon pump in three patients, all of whom had their intraaortic balloon pump placed percutaneously through mature grafts. Two of these required surgical thrombectomy. Ten intraaortic balloon pump insertions in eight patients survived the hospitalization and were followed for a mean of 24 months (range, 2 weeks to 64 months). No localized groin or graft infections were identified. No bleeding complications or pseudoaneurysms occurred. Thus in patients with unstable, severe, cardiac disease, intraaortic balloon pumps can be safely placed through indwelling suprainguinal bypass grafts.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1828091     DOI: 10.1067/mva.1991.28413

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  2 in total

1.  Transbrachial intra-aortic balloon pumping for high-risk percutaneous coronary intervention.

Authors:  Konstantinos Aznaouridis; Andro G Kacharava; Michelle Consolini; A Maziar Zafari; Kreton Mavromatis
Journal:  Am J Med Sci       Date:  2011-02       Impact factor: 2.378

2.  Transbrachial insertion of an intra-aortic balloon pump for high-risk percutaneous coronary intervention.

Authors:  Trevor Simard; Benjamin Hibbert; Brendan Parfrey; Edward R O'Brien
Journal:  Clin Res Cardiol       Date:  2012-05-03       Impact factor: 5.460

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.