Literature DB >> 18280057

Observations on real-time prostate gland motion using electromagnetic tracking.

Katja M Langen1, Twyla R Willoughby, Sanford L Meeks, Anand Santhanam, Alexis Cunningham, Lisa Levine, Patrick A Kupelian.   

Abstract

PURPOSE: To quantify and describe the real-time movement of the prostate gland in a large data set of patients treated with radiotherapy. METHODS AND MATERIALS: The Calypso four-dimensional localization system was used for target localization in 17 patients, with electromagnetic markers implanted in the prostate of each patient. We analyzed a total of 550 continuous tracking sessions. The fraction of time that the prostate was displaced by >3, >5, >7, and >10 mm was calculated for each session and patient. The frequencies of displacements after initial patient positioning were analyzed over time.
RESULTS: Averaged over all patients, the prostate was displaced >3 and >5 mm for 13.6% and 3.3% of the total treatment time, respectively. For individual patients, the corresponding maximal values were 36.2% and 10.9%. For individual fractions, the corresponding maximal values were 98.7% and 98.6%. Displacements >3 mm were observed at 5 min after initial alignment in about one-eighth of the observations, and increased to one-quarter by 10 min. For individual patients, the maximal value of the displacements >3 mm at 5 and 10 min after initial positioning was 43% and 75%, respectively.
CONCLUSION: On average, the prostate was displaced by >3 mm and >5 mm approximately 14% and 3% of the time, respectively. For individual patients, these values were up to three times greater. After the initial positioning, the likelihood of displacement of the prostate gland increased with elapsed time. This highlights the importance of initiating treatment shortly after initially positioning the patient.

Entities:  

Mesh:

Year:  2008        PMID: 18280057     DOI: 10.1016/j.ijrobp.2007.11.054

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  117 in total

1.  Image-based dynamic multileaf collimator tracking of moving targets during intensity-modulated arc therapy.

Authors:  Per Rugaard Poulsen; Walther Fledelius; Byungchul Cho; Paul Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-03-06       Impact factor: 7.038

2.  Reduction of dosimetric impact of intrafractional prostate motion during helical tomotherapy.

Authors:  V Prokic; H Geinitz; P Kneschaurek
Journal:  Strahlenther Onkol       Date:  2012-02-16       Impact factor: 3.621

Review 3.  A review of image-guided radiotherapy.

Authors:  George T Y Chen; Gregory C Sharp; Shinichiro Mori
Journal:  Radiol Phys Technol       Date:  2008-12-16

Review 4.  Technological advances in radiation therapy for prostate cancer.

Authors:  Mehee Choi; Arthur Y Hung
Journal:  Curr Urol Rep       Date:  2010-05       Impact factor: 3.092

5.  Dosimetric effect of intrafraction motion and residual setup error for hypofractionated prostate intensity-modulated radiotherapy with online cone beam computed tomography image guidance.

Authors:  Justus Adamson; Qiuwen Wu; Di Yan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-18       Impact factor: 7.038

Review 6.  Stereotactic body radiation therapy in primary hepatocellular carcinoma: current status and future directions.

Authors:  Timothy A Lin; Jessica S Lin; Timothy Wagner; Ngoc Pham
Journal:  J Gastrointest Oncol       Date:  2018-10

7.  Observation of intrafraction prostate displacement through the course of conventionally fractionated radiotherapy for prostate cancer.

Authors:  Yasushi Hamamoto; Hiroki Inata; Noritaka Sodeoka; Shigeki Nakayama; Shintaro Tsuruoka; Hideki Takeda; Toshiharu Manabe; Teruhito Mochizuki; Masakichi Umeda
Journal:  Jpn J Radiol       Date:  2015-02-08       Impact factor: 2.374

8.  A multi-GPU real-time dose simulation software framework for lung radiotherapy.

Authors:  A P Santhanam; Y Min; H Neelakkantan; N Papp; S L Meeks; P A Kupelian
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-04-27       Impact factor: 2.924

9.  Optimizing monoscopic kV fluoro acquisition for prostate intrafraction motion evaluation.

Authors:  Justus Adamson; Qiuwen Wu
Journal:  Phys Med Biol       Date:  2008-12-10       Impact factor: 3.609

10.  Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy.

Authors:  Tobias Pommer; Marianne Falk; Per R Poulsen; Paul J Keall; Ricky T O'Brien; Peter Meidahl Petersen; Per Munck af Rosenschöld
Journal:  Phys Med Biol       Date:  2013-03-14       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.