BACKGROUND: Measurement of vitamin D molecules are important in the management of patients with bone disease. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to measure 25OHD(3) and 25OHD(2) in human serum and compared it to the traditionally used DiaSorin radioimmunoassay (RIA). METHODS: Serum samples (200 microl) were treated with acetonitrile and centrifuged to remove protein. An online solid-phase extraction procedure was used. Calibration solutions (5-100 ng/ml) of 25OHD(2) and 25OHD(3) were prepared using 4% albumin in phosphate-buffered saline. Chromatography: C18 column, isocratic ethanol/water (83/17, v/v). Mass spectrometry system: atmospheric pressure chemical ionization in the positive ion mode. Transitions: 25OHD(3), m/z 401.4-->383.4; 25OHD(2), m/z 413.4-->395.4; and the internal standard hexadeuterated-25OHD(3), m/z 407.7-->389.7. RESULTS: Detection limits were 0.49 ng/ml (25OHD(3)) and 1.86 ng/ml (25OHD(2)). Intra- and inter-assay coefficients of variation (CV) were <7% and <11%, respectively, for 25OHD(3) and <9% and <16%, respectively, for 25OHD(2). Recovery averaged (SD) 99% (2%) for 25OHD(3) and 95% (0.8%) for 25OHD(2). In a method comparison of 551 specimens from the National Health and Nutrition Examination Survey, the LC-MS/MS method gave values that were on average 13% higher (95%CI: 11-15%) than RIA results. CONCLUSIONS: This high throughput candidate reference method requires minimal sample preparation and is suitable for routine use for analysis of vitamin D status.
BACKGROUND: Measurement of vitamin D molecules are important in the management of patients with bone disease. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to measure 25OHD(3) and 25OHD(2) in human serum and compared it to the traditionally used DiaSorin radioimmunoassay (RIA). METHODS: Serum samples (200 microl) were treated with acetonitrile and centrifuged to remove protein. An online solid-phase extraction procedure was used. Calibration solutions (5-100 ng/ml) of 25OHD(2) and 25OHD(3) were prepared using 4% albumin in phosphate-buffered saline. Chromatography: C18 column, isocratic ethanol/water (83/17, v/v). Mass spectrometry system: atmospheric pressure chemical ionization in the positive ion mode. Transitions: 25OHD(3), m/z 401.4-->383.4; 25OHD(2), m/z 413.4-->395.4; and the internal standard hexadeuterated-25OHD(3), m/z 407.7-->389.7. RESULTS: Detection limits were 0.49 ng/ml (25OHD(3)) and 1.86 ng/ml (25OHD(2)). Intra- and inter-assay coefficients of variation (CV) were <7% and <11%, respectively, for 25OHD(3) and <9% and <16%, respectively, for 25OHD(2). Recovery averaged (SD) 99% (2%) for 25OHD(3) and 95% (0.8%) for 25OHD(2). In a method comparison of 551 specimens from the National Health and Nutrition Examination Survey, the LC-MS/MS method gave values that were on average 13% higher (95%CI: 11-15%) than RIA results. CONCLUSIONS: This high throughput candidate reference method requires minimal sample preparation and is suitable for routine use for analysis of vitamin D status.
Authors: Karen W Phinney; Mary Bedner; Susan S-C Tai; Veronica V Vamathevan; Lane C Sander; Katherine E Sharpless; Stephen A Wise; James H Yen; Rosemary L Schleicher; Madhulika Chaudhary-Webb; Christine M Pfeiffer; Joseph M Betz; Paul M Coates; Mary Frances Picciano Journal: Anal Chem Date: 2011-12-28 Impact factor: 6.986
Authors: Elizabeth A Yetley; Christine M Pfeiffer; Rosemary L Schleicher; Karen W Phinney; David A Lacher; Sylvia Christakos; John H Eckfeldt; James C Fleet; George Howard; Andrew N Hoofnagle; Siu L Hui; Gary L Lensmeyer; Joseph Massaro; Munro Peacock; Bernard Rosner; Donald Wiebe; Regan L Bailey; Paul M Coates; Anne C Looker; Christopher Sempos; Clifford L Johnson; Mary Frances Picciano Journal: J Nutr Date: 2010-09-29 Impact factor: 4.798
Authors: Miguel Angel Luque-Fernandez; Bizu Gelaye; Tyler VanderWeele; Cynthia Ferre; Anna Maria Siega-Riz; Claudia Holzman; Daniel A Enquobahrie; Nancy Dole; Michelle A Williams Journal: Paediatr Perinat Epidemiol Date: 2013-12-20 Impact factor: 3.980
Authors: Conrad R Cole; Frederick K Grant; Vin Tangpricha; E Dawn Swaby-Ellis; Joy L Smith; Anne Jacques; Huiping Chen; Rosemary L Schleicher; Thomas R Ziegler Journal: Pediatrics Date: 2010-03-29 Impact factor: 7.124
Authors: Yan Tian; Claudia Holzman; Anna M Siega-Riz; Michelle A Williams; Nancy Dole; Daniel A Enquobahrie; Cynthia D Ferre Journal: Paediatr Perinat Epidemiol Date: 2015-11-17 Impact factor: 3.980