Literature DB >> 18277843

Veinlite transillumination in the pediatric emergency department: a therapeutic interventional trial.

Yiannis L Katsogridakis1, Roopa Seshadri, Christine Sullivan, Mark L Waltzman.   

Abstract

OBJECTIVES: We hypothesized that transillumination would increase peripheral intravenous (IV) insertion success rates in pediatric emergency department patients. Primary outcome was success in first attempt, and secondary outcome was success within 2 attempts.
METHODS: We evaluated IV insertion by pediatric emergency department physicians and nurses using the Veinlite (TransLite, Sugar Land, Tex). Patients who required nonemergent IV insertion were enrolled if younger than 3 years or aged 3 to 21 years with a history of difficult access. Participants were randomly assigned to transillumination or nontransillumination. Analyses were performed using a mixed-effects logistic regression model adjusting for provider effect.
RESULTS: We evaluated 240 patients. After adjusting for significant covariates (safety catheter [P = 0.008], visibility [P = 0.01], and palpability [P = 0.03]) and controlling for provider effect, IV placement was more likely successful in first attempt in transilluminated patients (P = 0.03; odds ratio, 2.1 [95% confidence interval, 1.1-3.9]). After adjusting for significant covariates (safety catheter [P < 0.001], location [P = 0.005], and palpability [P = 0.05]) and controlling for provider effect, IV placement was more likely successful within 2 attempts in transilluminated patients (P = 0.01; odds ratio, 3.5 [95% confidence interval, 1.4-8.9]). Intracluster correlation for random effect of provider was 10% in first attempt and 16% within 2 attempts.
CONCLUSIONS: After adjusting for multiple significant covariates and controlling for random effect of provider, our results indicated a benefit in the use of Veinlite transillumination for IV insertion in first attempt and within 2 attempts. This technique seemed to facilitate nonemergent IV placement in pediatric patients compared with standard practice.

Entities:  

Mesh:

Year:  2008        PMID: 18277843     DOI: 10.1097/PEC.0b013e318163db5f

Source DB:  PubMed          Journal:  Pediatr Emerg Care        ISSN: 0749-5161            Impact factor:   1.454


  16 in total

Review 1.  Utility of near-infrared light devices for pediatric peripheral intravenous cannulation: a systematic review and meta-analysis.

Authors:  Joon Min Park; Min Joung Kim; Hyeon Woo Yim; Won-Chul Lee; Hyunsuk Jeong; Na Jin Kim
Journal:  Eur J Pediatr       Date:  2016-10-26       Impact factor: 3.183

2.  Utilization of a biomedical device (VeinViewer® ) to assist with peripheral intravenous catheter (PIV) insertion for pediatric nurses.

Authors:  Heidi L McNeely; Theresa L Ream; Jodi M Thrasher; Oliwier Dziadkowiec; Tiffany J Callahan
Journal:  J Spec Pediatr Nurs       Date:  2018-02-10       Impact factor: 1.260

3.  Pen Torch Transillumination: Difficult Venepuncture Made Easy.

Authors:  Elijah Zhengyang Cai; Kalarani Sankaran; Monica Tan; Yiong Huak Chan; Thiam Chye Lim
Journal:  World J Surg       Date:  2017-09       Impact factor: 3.352

4.  Ultrasound or near-infrared vascular imaging to guide peripheral intravenous catheterization in children: a pragmatic randomized controlled trial.

Authors:  Sarah J Curtis; William R Craig; Erin Logue; Ben Vandermeer; Amanda Hanson; Terry Klassen
Journal:  CMAJ       Date:  2015-04-20       Impact factor: 8.262

5.  Portable robot for autonomous venipuncture using 3D near infrared image guidance.

Authors:  Alvin Chen; Kevin Nikitczuk; Jason Nikitczuk; Tim Maguire; Martin Yarmush
Journal:  Technology (Singap World Sci)       Date:  2013-09

6.  Efficacy of VeinViewer in pediatric peripheral intravenous access: a randomized controlled trial.

Authors:  Min Joung Kim; Joon Min Park; Nuga Rhee; Sang Mo Je; Seong Hee Hong; Young Mock Lee; Sung Phil Chung; Seung Ho Kim
Journal:  Eur J Pediatr       Date:  2012-03-14       Impact factor: 3.183

7.  First-in-human evaluation of a hand-held automated venipuncture device for rapid venous blood draws.

Authors:  Josh M Leipheimer; Max L Balter; Alvin I Chen; Enrique J Pantin; Alexander E Davidovich; Kristen S Labazzo; Martin L Yarmush
Journal:  Technology (Singap World Sci)       Date:  2020-01-22

8.  The System Design and Evaluation of a 7-DOF Image-Guided Venipuncture Robot.

Authors:  Max L Balter; Alvin I Chen; Timothy J Maguire; Martin L Yarmush
Journal:  IEEE Trans Robot       Date:  2015-08       Impact factor: 5.567

9.  Independent finger-mounted device for vein visualization.

Authors:  Elijah Zhengyang Cai; Raymond Sui Ming Hon; Wai Tung Chow; Ching-Chiuan Yen; Thiam Chye Lim
Journal:  Arch Plast Surg       Date:  2021-05-15

10.  Optical characterization of cutaneous transilluminators for eye safety.

Authors:  Sharon Miller; Robert James; Robert Landry; Joshua Pfefer
Journal:  Biomed Opt Express       Date:  2010-09-02       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.