Literature DB >> 18276930

Indirect bonding--a new transfer method.

B Wendl1, H Droschl, P Muchitsch.   

Abstract

The aim of this in vitro study was to investigate both shear bond strength (SBS) by shear testing of indirectly bonded brackets, and the accuracy of a new transfer method, the Aptus bonding device (ABD). For comparison, the SBS of directly bonded brackets in two experimental arrangements was also measured. The precision of the positioning of the indirect bracket transfer was assessed by photographic superimposition and three-dimensional (3D) measurement of the bracket positions on the working and plaster models using a 3D laser scan. Statistical analysis was carried out by means of descriptive and explorative data using the SPSS program. To compare groups, a one-factor analysis of variance and post hoc tests (Tukey-HSD) were used. The level of significance was set at P < 0.05. SBS using indirect and direct bonding, with the same experimental arrangement and the same adhesives (Concise and Transbond), showed no significant differences. For direct bonding, using only one adhesive (Transbond), lower values were observed, but they were only statistically significant for the premolar teeth. The clinically required minimum bond strength of 6 MPa was achieved in all groups. Superimposition of the photographs of the indirectly bonded upper labial segment brackets showed no deviations. The results of the 3D measurement of the positions of the brackets on the working and plaster models only yielded small deviations (0.15 mm along the X-axis in the centre, 0.17 mm along the Y-axis, and 0.19 mm along the Z-axis). The ABD is a useful adjunct to bond placement and does not compromise bond strength.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18276930     DOI: 10.1093/ejo/cjm094

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  5 in total

1.  Indirect orthodontic bonding--a modified technique for improved efficiency and precision.

Authors:  Lincoln Issamu Nojima; Adriele Silveira Araújo; Matheus Alves Júnior
Journal:  Dental Press J Orthod       Date:  2015 May-Jun

2.  Precision of indirect bonding of lingual brackets using the Quick Modul System (QMS)®.

Authors:  Katharina Schubert; Thomas Halbich; Paul-Georg Jost-Brinkmann; Ralf Müller-Hartwich
Journal:  J Orofac Orthop       Date:  2013-01-10       Impact factor: 1.938

Review 3.  Bracket Transfer Accuracy with the Indirect Bonding Technique-A Systematic Review and Meta-Analysis.

Authors:  Hisham Sabbagh; Yeganeh Khazaei; Uwe Baumert; Lea Hoffmann; Andrea Wichelhaus; Mila Janjic Rankovic
Journal:  J Clin Med       Date:  2022-05-04       Impact factor: 4.964

4.  Effectiveness, efficiency and adverse effects of using direct or indirect bonding technique in orthodontic patients: a systematic review and meta-analysis.

Authors:  Yanxi Li; Li Mei; Jieya Wei; Xinyu Yan; Xu Zhang; Wei Zheng; Yu Li
Journal:  BMC Oral Health       Date:  2019-07-08       Impact factor: 2.757

5.  Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study.

Authors:  Jae-Hyun Park; Jin-Young Choi; Seong-Hun Kim; Su-Jung Kim; Kee-Joon Lee; Gerald Nelson
Journal:  Korean J Orthod       Date:  2021-11-25       Impact factor: 1.372

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.