Literature DB >> 18275454

Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure.

Heidi Harbison Kimberly1, Sachita Shah, Keith Marill, Vicki Noble.   

Abstract

BACKGROUND: Measurements of the optic nerve sheath diameter (ONSD) using bedside ultrasound (US) have been shown to correlate with clinical and radiologic signs and symptoms of increased intracranial pressure (ICP).
OBJECTIVES: Previous literature has identified 5 mm as the ONSD measurement above which patients exhibit either clinical or radiologic signs of elevated ICP. The goals of this study were to evaluate the association between ONSD and ICP and to validate the commonly used ONSD threshold of 5 mm using direct measurements of ICP as measured by ventriculostomy.
METHODS: A prospective blinded observational study was performed using a convenience sample of adult patients in both the emergency department (ED) and the neurologic intensive care unit (ICU) who had invasive intracranial monitors placed as part of their clinical care. Ocular USs were performed with a 10(-5) MHz linear probe. Emergency physicians (EPs) with previous ocular US experience performed ONSD measurements while blinded to the contemporaneous ICP reading obtained directly from invasive monitoring. The association between ONSD and ICP was assessed with the Spearman rank correlation coefficient, and a receiver operator characteristic (ROC) curve was created to determine the optimal ONSD cutoff to detect ICP > 20 cm H2O.
RESULTS: Thirty-eight ocular USs were performed on 15 individual patients. Spearman rank correlation coefficient of ONSD and ICP was 0.59 (p < 0.0005) demonstrating a significant positive correlation. An ROC curve was created to assess the ability of ONSD to distinguish an abnormal ICP greater than 20 cm H2O. The area under the ROC curve was 0.93 (95% confidence interval [CI] = 0.84 to 0.99). Based on inspection of the ROC curve, ONSD > 5 mm performed well to detect ICP > 20 cm H(2)O with a sensitivity of 88% (95% CI = 47% to 99%) and specificity of 93% (95% CI = 78% to 99%).
CONCLUSIONS: Using an ROC curve the authors systematically confirmed the commonly used threshold of ONSD > 5 mm to detect ICP > 20 cm H2O. This study directly correlates ventriculostomy measurements of ICP with US ONSD measurements and provides further support for the use of ONSD measurements as a noninvasive test for elevated ICP.

Entities:  

Mesh:

Year:  2008        PMID: 18275454     DOI: 10.1111/j.1553-2712.2007.00031.x

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  125 in total

Review 1.  Point-of-care ultrasound education to improve care of dialysis patients.

Authors:  Surekha Mullangi; Stephen M Sozio; Paul Segal; Steven Menez; Carol Martire; Tariq Shafi
Journal:  Semin Dial       Date:  2018-01-03       Impact factor: 3.455

2.  A systematic study of linear dynamic modeling of intracranial pressure dynamics.

Authors:  Sunghan Kim; Marvin Bergsneider; Xiao Hu
Journal:  Physiol Meas       Date:  2011-02-01       Impact factor: 2.833

Review 3.  Current concepts and strategies in the diagnosis and management of idiopathic intracranial hypertension in adults.

Authors:  Jane W Chan
Journal:  J Neurol       Date:  2017-01-31       Impact factor: 4.849

4.  Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage.

Authors:  Riccardo Moretti; Barbara Pizzi; Fabrizio Cassini; Nicoletta Vivaldi
Journal:  Neurocrit Care       Date:  2009-12       Impact factor: 3.210

5.  Non-invasive methods of estimating intracranial pressure.

Authors:  Jamie B Rosenberg; Ariel L Shiloh; Richard H Savel; Lewis A Eisen
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

Review 6.  Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis.

Authors:  Julie Dubourg; Etienne Javouhey; Thomas Geeraerts; Mahmoud Messerer; Behrouz Kassai
Journal:  Intensive Care Med       Date:  2011-04-20       Impact factor: 17.440

7.  Ultrasonography Assessments of Optic Nerve Sheath Diameter as a Noninvasive and Dynamic Method of Detecting Changes in Intracranial Pressure.

Authors:  Li-Juan Wang; Li-Min Chen; Ying Chen; Li-Yang Bao; Nan-Nan Zheng; Yu-Zhi Wang; Ying-Qi Xing
Journal:  JAMA Ophthalmol       Date:  2018-03-01       Impact factor: 7.389

8.  Analysis of cerebral blood flow and intracranial hypertension in critical patients with non-hepatic hyperammonemia.

Authors:  Alexandre Sanches Larangeira; Marcos Toshiyuki Tanita; Marcos Antonio Dias; Olavo Franco Ferreira Filho; Vinicius Daher Alvares Delfino; Lucienne Tibery Queiroz Cardoso; Cintia Magalhães Carvalho Grion
Journal:  Metab Brain Dis       Date:  2018-05-03       Impact factor: 3.584

9.  Management of hepatic encephalopathy.

Authors:  Jennifer A Frontera
Journal:  Curr Treat Options Neurol       Date:  2014-06       Impact factor: 3.598

10.  Ophthalmodynamometry for ICP prediction and pilot test on Mt. Everest.

Authors:  Henry W Querfurth; Philip Lieberman; Steve Arms; Steve Mundell; Michael Bennett; Craig van Horne
Journal:  BMC Neurol       Date:  2010-11-01       Impact factor: 2.474

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.