Literature DB >> 1827397

Influence of sample type on the interpretation of the oral glucose tolerance test for gestational diabetes mellitus.

R D Neely1, J B Kiwanuka, D R Hadden.   

Abstract

The World Health Organization (1985) criteria allow evaluation of the oral glucose tolerance test using venous or capillary whole blood or plasma glucose measurements. However, the empirical factors used for interconversion may not reflect observed differences, especially during pregnancy, causing inconsistent classification. To investigate how choice of sample would influence the interpretation of results, venous and capillary blood was taken during oral glucose tolerance tests in 36 pregnant women at risk of gestational diabetes and in 21 non-pregnant control subjects. Glucose was measured on whole blood and plasma by a glucose oxidase method. No cases of gestational diabetes were identified. Eight subjects had gestational Impaired Glucose Tolerance using either venous plasma or venous whole blood results, but only five were similarly classified with capillary whole blood and only four using capillary plasma. Plasma-whole blood differences (venous 0.6 +/- 0.2 (+/- SD) mmol l-1, capillary 0.7 +/- 0.3 mmol l-1) and capillary-venous differences (plasma 0.5 +/- 0.4, whole blood 0.4 +/- 0.5 mmol l-1) at 2 h were lower (all p less than 0.05) than in the WHO criteria (1.1 mmol l-1). When compared with venous plasma, capillary measurements may give a lower incidence and venous whole blood measurements a higher incidence of Impaired Glucose Tolerance in pregnancy.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1827397     DOI: 10.1111/j.1464-5491.1991.tb01558.x

Source DB:  PubMed          Journal:  Diabet Med        ISSN: 0742-3071            Impact factor:   4.359


  5 in total

Review 1.  Challenges to glycemic measurement in the perioperative and critically ill patient: a review.

Authors:  Andrew D Pitkin; Mark J Rice
Journal:  J Diabetes Sci Technol       Date:  2009-11-01

2.  Diabetes care in the dispersed population of Greenland. A new model based on continued monitoring, analysis and adjustment of initiatives taken.

Authors:  Michael Lynge Pedersen
Journal:  Int J Circumpolar Health       Date:  2019       Impact factor: 1.228

3.  Performance evaluation of three i-SENS glucometers using arterial blood samples compared with the YSI 2300 Glucose Analyzer.

Authors:  Ha Nui Kim; Kyung Chul Moon; Soo-Young Yoon
Journal:  J Clin Lab Anal       Date:  2020-05-19       Impact factor: 2.352

Review 4.  Accuracy of blood-glucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: systematic review.

Authors:  Shigeaki Inoue; Moritoki Egi; Joji Kotani; Kiyoshi Morita
Journal:  Crit Care       Date:  2013-03-18       Impact factor: 9.097

5.  Gestational diabetes mellitus in Greenland: a national study of prevalence and testing efficacy.

Authors:  Michael Lynge Pedersen; Jesper Olesen; Marit Eika Jørgensen; Peter Damm
Journal:  Int J Circumpolar Health       Date:  2016-08-24       Impact factor: 1.228

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.