Literature DB >> 18271373

Retention of zirconia ceramic copings bonded to titanium abutments.

Agnes Ebert1, Juergen Hedderich, Matthias Kern.   

Abstract

PURPOSE: The aim of this study was to evaluate the effect of 2 surface conditioning methods and 2 luting-gap sizes on the retention and durability of zirconia ceramic copings bonded to titanium abutments.
MATERIALS AND METHODS: Zirconia ceramic copings (Camlog Biotechnologies, Winsheim, Germany) with a luting-gap size of either 30 microm or 60 microm were bonded to titanium abutments (Camlog Biotechnologies) using the composite resin cement Panavia F (Kuraray, Osaka, Japan). The bonding surfaces of the zirconia ceramic copings were either (a) pretreated with airborne particle abrasion and cleaned with alcohol or (b) just cleaned with alcohol, whereas the bonding surfaces of all titanium abutments had been abraded and cleaned. After the specimens had been stressed for either 1, 30, 60, or 150 days by water and thermal cycling, retention was measured.
RESULTS: The surface conditioning method, luting-gap size, and storage time significantly (P = .001; 3-way analysis of variance [ANOVA]) influenced retention. Air abrasion increased the retention significantly. Failure modes were predominantly adhesive. Air-abraded copings bonded with 30-microm luting gap achieved significantly greater retention than those bonded with a 60-microm luting gap.
CONCLUSION: Surface conditioning methods and the size of the luting gap have a significant influence on the retention of Camlog zirconia ceramic copings bonded to Camlog titanium abutments.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18271373

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  8 in total

1.  Biologic and Esthetic Outcome of CAD/CAM Custom Ceramic Implant Abutment: A Clinical Report.

Authors:  Ioana Monica Valsan; Mihaela Rodica Pauna; Alexandru Eugen Petre; Luminita Oancea
Journal:  Maedica (Bucur)       Date:  2021-03

2.  Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments.

Authors:  Sina Safari; Fereshteh Hosseini Ghavam; Parviz Amini; Kaveh Yaghmaei
Journal:  J Adv Prosthodont       Date:  2018-02-12       Impact factor: 1.904

3.  Effects of Liner-Bonding of Implant-Supported Glass-Ceramic Crown to Zirconia Abutment on Bond Strength and Fracture Resistance.

Authors:  Yong-Seok Jang; Sang-Hoon Oh; Won-Suck Oh; Min-Ho Lee; Jung-Jin Lee; Tae-Sung Bae
Journal:  Materials (Basel)       Date:  2019-08-30       Impact factor: 3.623

4.  In vitro evaluation of the influence of titanium nitride coating on the retention force between components of two-part abutments.

Authors:  Nadine Freifrau von Maltzahn; Jan Holstermann; Meike Stiesch; Philipp Kohorst
Journal:  BMC Oral Health       Date:  2021-06-02       Impact factor: 2.757

5.  Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro.

Authors:  Felix Dähne; Heike Meißner; Klaus Böning; Christin Arnold; Ralf Gutwald; Elisabeth Prause
Journal:  Int J Implant Dent       Date:  2021-07-20

6.  The effect of resin cements and primer on retentive force of zirconia copings bonded to zirconia abutments with insufficient retention.

Authors:  Seung-Mi Kim; Ji-Young Yoon; Myung-Hyun Lee; Nam-Sik Oh
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

7.  Comparative evaluation of bonding strength of computer aided machined ceramic, pressable ceramic, and milled metal implant abutment copings and effect of surface conditioning on bonding strength: An in vitro study.

Authors:  Sapna Rani; Mahesh Verma; Shubhra Gill; Rekha Gupta
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

8.  Assessment and comparison of retention of zirconia copings luted with different cements onto zirconia and titanium abutments: An in vitro study.

Authors:  Neelima Sreekumar Menon; G P Surendra Kumar; K R Jnanadev; C L Satish Babu; Shilpa Shetty
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.