Literature DB >> 18269981

QRS slopes for detection and characterization of myocardial ischemia.

Esther Pueyo1, Leif Sornmo, Pablo Laguna.   

Abstract

In this study, the upward I(US) and downward I(DS) slopes of the QRS complex are proposed as indices for quantifying ischemia-induced electrocardiogram (ECG) changes. Using ECG recordings acquired before and during percutaneous transluminal coronary angioplasty (PTCA), it is found that the QRS slopes are considerably less steep during artery occlusion, in particular for I(DS). With respect to ischemia detection, the slope indices outperform the often used high-frequency index (defined as the root mean square (rms) of the bandpass-filtered QRS signal for the frequency band 150-250 Hz) as the mean relative factors of change are much larger for I(US) and I(DS) than for the high-frequency index (6.9 and 7.3 versus 3.7). The superior performance of the slope indices is equally valid when other frequency bands of the high-frequency index are investigated (the optimum one is found to be 125-175 Hz). Employing a simulation model in which the slopes of a template QRS are altered by different techniques, it is found that the slope changes observed during PTCA are mostly due to a widening of the QRS complex or a decrease of its amplitudes, but not a reduction of its high-frequency content or a combination of this and the previous effects. It is concluded that QRS slope information can be used as an adjunct to the conventional ST segment analysis in the monitoring of myocardial ischemia.

Entities:  

Mesh:

Year:  2008        PMID: 18269981     DOI: 10.1109/TBME.2007.902228

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  9 in total

1.  Characterization of QT and RR interval series during acute myocardial ischemia by means of recurrence quantification analysis.

Authors:  Yi Peng; Zhongwei Sun
Journal:  Med Biol Eng Comput       Date:  2010-08-20       Impact factor: 2.602

2.  Based Real Time Remote Health Monitoring Systems: A Review on Patients Prioritization and Related "Big Data" Using Body Sensors information and Communication Technology.

Authors:  Naser Kalid; A A Zaidan; B B Zaidan; Omar H Salman; M Hashim; H Muzammil
Journal:  J Med Syst       Date:  2017-12-29       Impact factor: 4.460

3.  "ECG variability contour" method reveals amplitude changes in both ischemic patients and normal subjects during Dipyridamole stress: a preliminary report.

Authors:  Guy Dori; Michal Gershinsky; Simona Ben-Haim; Basil S Lewis; Haim Bitterman
Journal:  Med Biol Eng Comput       Date:  2011-10-04       Impact factor: 2.602

4.  Monitoring of Serum Potassium and Calcium Levels in End-Stage Renal Disease Patients by ECG Depolarization Morphology Analysis.

Authors:  Hassaan A Bukhari; Carlos Sánchez; José Esteban Ruiz; Mark Potse; Pablo Laguna; Esther Pueyo
Journal:  Sensors (Basel)       Date:  2022-04-12       Impact factor: 3.847

Review 5.  A Review of Automated Methods for Detection of Myocardial Ischemia and Infarction Using Electrocardiogram and Electronic Health Records.

Authors:  Sardar Ansari; Negar Farzaneh; Marlena Duda; Kelsey Horan; Hedvig B Andersson; Zachary D Goldberger; Brahmajee K Nallamothu; Kayvan Najarian
Journal:  IEEE Rev Biomed Eng       Date:  2017-10-16

6.  A novel low-complexity post-processing algorithm for precise QRS localization.

Authors:  Pedro Fonseca; Ronald M Aarts; Jérôme Foussier; Xi Long
Journal:  Springerplus       Date:  2014-07-25

7.  High arrhythmic risk in antero-septal acute myocardial ischemia is explained by increased transmural reentry occurrence.

Authors:  Hector Martinez-Navarro; Ana Mincholé; Alfonso Bueno-Orovio; Blanca Rodriguez
Journal:  Sci Rep       Date:  2019-11-14       Impact factor: 4.379

8.  R-Wave Singularity: A New Morphological Approach to the Analysis of Cardiac Electrical Dyssynchrony.

Authors:  Ping Zhan; Tao Li; Jinlong Shi; Guojing Wang; Buqing Wang; Hongyun Liu; Weidong Wang
Journal:  Front Physiol       Date:  2020-12-22       Impact factor: 4.566

9.  Implementation of a portable device for real-time ECG signal analysis.

Authors:  Taegyun Jeon; Byoungho Kim; Moongu Jeon; Byung-Geun Lee
Journal:  Biomed Eng Online       Date:  2014-12-10       Impact factor: 2.819

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.