Literature DB >> 18269483

Failure strengths of concentric and eccentric implants for hamstring graft fixation.

David P Gwynne-Jones1, Joanne Draffin, Andrew G S Vane, Roy A Craig, Simon F McMahon.   

Abstract

The purpose of this study is to compare the initial failure strengths of various interference screw devices used for tibial fixation of hamstring grafts in anterior cruciate ligament reconstruction and the effect of concentric or eccentric screw position. Quadrupled tendon grafts were harvested from freshly killed sheep. The grafts were then prepared and fixed in the distal femur using various devices (Intrafix (DePuy Mitek Raynham, MA, USA), RCI screw (Smith and Nephew Acufex, Mansfield, MA, USA), Wedge screw (Stryker Endoscopy, San Jose, CA, USA) in concentric position and Wedge screw in eccentric position with an interlock pin). The load required to cause mechanical failure of each construct was measured. The Intrafix device had a significantly greater mean strength to failure than all the other implants (mean 941 +/- 280 N) (P = 0.015 to P < 0.0001). The wedge screw inserted concentrically (737 +/- 134 N) had significantly greater initial failure strength than the wedge eccentric with interlock pin (458 +/- 266 N) (P = 0.03) and the RCI screw (464 +/- 107 N) (P = 0.00036). In this sheep model the Intrafix device with sheath inserted concentrically had significantly greater initial failure strength than the other interference screws. Concentric positioning of the wedge interference screw gave significantly greater initial failure strength of a quadruple tendon graft than eccentric positioning. The use of the Intrafix device or concentric positioning of an interference screw should result in increased initial fixation strength of hamstring grafts. This may allow more vigorous early rehabilitation and may result in less late graft laxity after anterior cruciate ligament reconstruction.

Entities:  

Mesh:

Year:  2008        PMID: 18269483     DOI: 10.1111/j.1445-2197.2007.04397.x

Source DB:  PubMed          Journal:  ANZ J Surg        ISSN: 1445-1433            Impact factor:   1.872


  2 in total

1.  Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods.

Authors:  Christian Carulli; Fabrizio Matassi; Stefano Soderi; Luigi Sirleo; Giovanni Munz; Massimo Innocenti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-27       Impact factor: 4.342

2.  Investigation of Hamstring Tendon Graft Fixation for the Reconstruction of Anterior Cruciate Ligament using Interference Screw Merely or in Combination with Supplementary Staple: A Clinical Trial.

Authors:  Sayed Hamid Mousavi; Omid Masoumi; Hossein Akbariaghdam; Ghasem Mohammadsharifi
Journal:  Adv Biomed Res       Date:  2020-09-30
  2 in total