Literature DB >> 18269480

Tensile strength of surgical knots in abdominal wound closure.

Eva D M Fong1, Adam S R Bartlett, Sharif Malak, Iain A Anderson.   

Abstract

Abdominal wound dehiscence is a surgical catastrophe that can be attributed to patients or technical factors. The technical properties of the monofilament sutures and knots that are commonly used in abdominal closure are poorly understood. The aim of this study was to compare the tensile strength of monofilament sutures tied with conventional knots. To do this, the knot-holding capacity of four types of knots (square, surgeons', Aberdeen and loop) were tested using three types of gauge 1 monofilament suture, namely nylon, polyglyconate and polydioxanone, using a tensiometer. We found that the knot-holding capacity of the loop knot was between twofold and threefold greater than all the other knots examined. In comparing suture types, polyglyconate had the highest knot-holding capacity for all the knots that were examined and there was no difference in the tensile strength of nylon and polyglyconate tied in a square, surgeons' or Aberdeen knot (P < 0.05). In conclusion, our findings suggest that closure of an abdominal wound would be best commenced with a loop knot, using gauge 1 polyglyconate and finished with either an Aberdeen square or surgeons' knot would be appropriate.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18269480     DOI: 10.1111/j.1445-2197.2007.04394.x

Source DB:  PubMed          Journal:  ANZ J Surg        ISSN: 1445-1433            Impact factor:   1.872


  5 in total

1.  The Aberdeen 'continuous interrupted' surgical suturing technique.

Authors:  Kiran K Singisetti; George P Ashcroft
Journal:  Ann R Coll Surg Engl       Date:  2009-05       Impact factor: 1.891

2.  Beyond the square knot: a novel knotting technique for surgical use.

Authors:  Chunfeng Zhao; Chung-Chen Hsu; Tamami Moriya; Andrew R Thoreson; Steven S Cha; Steven L Moran; Kai-Nan An; Peter C Amadio
Journal:  J Bone Joint Surg Am       Date:  2013-06-05       Impact factor: 5.284

3.  Does loading velocity affect failure strength after tendon repair?

Authors:  Manoj Parimi; Chunfeng Zhao; Andrew R Thoreson; Kai-Nan An; Peter C Amadio
Journal:  J Biomech       Date:  2012-09-15       Impact factor: 2.712

4.  Comparison of polyglactin-910 and polydioxanone for closure of the linea alba following caudal ventral midline laparotomy in sheep.

Authors:  Marjolaine Rousseau; David E Anderson; Timothy G Rozell; Jacqelyn M Hand; Brian R Faris
Journal:  Can Vet J       Date:  2015-09       Impact factor: 1.008

5.  How to tie dangerous surgical knots: easily. Can we avoid this?

Authors:  Eric Drabble; Sofia Spanopoulou; Eleni Sioka; Ellie Politaki; Ismini Paraskeva; Effrosyni Palla; Lauren Stockley; Dimitris Zacharoulis
Journal:  BMJ Surg Interv Health Technol       Date:  2021-07-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.