Literature DB >> 18269135

Effect of denture cleansers on the hardness of heat- or auto-cured acrylic- or silicone-based soft denture liners.

Ayşe Meşe1.   

Abstract

PURPOSE: To investigate the effect of short (24 hours) and long term (6 months) exposure to a variety of commercially available denture cleanser solutions on the hardness of a variety of acrylic- and silicone-based resilient liners that were either heat- or auto-cured.
METHODS: The denture liners investigated were an acrylic-based heat-cured (Vertex Soft), acrylic-based auto-cured (Coe-Soft), a silicon-based heat-cured (Molloplast-B) and silicon-based auto-cured (Mollosil Plus) resilient liners. Cylindirical specimens (20 mm diameter, 12 mm high) were made of each material, using 10 replications for each test condition. Immersion solutions consisted of distilled water (control), and those based on alcohol, chlorhexidine, or an alkaline peroxide (Dermacol, aqueous chlorhexidine, Steradent) as a major active component. Specimens were fabricated according to manufacturer directions. Shore-A durameter hardness readings were taken on all specimens at each time interval and then compared statistically using four-way ANOVA and Tukey HSD (alpha = 0.05).
RESULTS: The results of this study indicated that, compared with distilled water, significant effect on the hardness of the specimens were found after immersion in all of the denture cleanser solutions at 24 hours and at 6 months. Specimens immersed in chlorhexidine showed higher and significant hardness changes than those immersed in other cleanser solutions. Also, it was determined that hardness of resilient liner materials increased with time and significantly higher hardness was recorded at 6 months for the auto-cured specimens compared with their heat-cured counterparts.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18269135

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  5 in total

1.  Disinfection of maxillofacial silicone elastomer using a novel antimicrobial agent: recombinant human beta-defensin-3.

Authors:  Y Shi; W Song; Z H Feng; Y T Zhao; F Li; Y Tian; Y M Zhao
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2008-10-08       Impact factor: 3.267

2.  Effect of ageing and immersion in different beverages on properties of denture lining materials.

Authors:  Vanessa M F Leite; Marina X Pisani; Helena F O Paranhos; Raphael F Souza; Cláudia H Silva-Lovato
Journal:  J Appl Oral Sci       Date:  2010 Jul-Aug       Impact factor: 2.698

3.  Comparison of Conventional Pressure-packed and Injection Molding Processing Methods for an Acrylic Resin Denture based on Microhardness, Surface Roughness, and Water Sorption.

Authors:  Elnaz Moslehifard; Tahereh Ghaffari; Hamidreza Abolghasemi; Solmaz Maleki Dizaj
Journal:  Int J Dent       Date:  2022-08-17

4.  Comparison of the Effect of two Denture Cleansers on Tensile bond Strength of a Denture Liner.

Authors:  M Farzin; F Bahrani; E Adelpour
Journal:  J Dent (Shiraz)       Date:  2013-09

5.  Effect of beverages on the hardness and tensile bond strength of temporary acrylic soft liners to acrylic resin denture base.

Authors:  A Safari; M Vojdani; S Mogharrabi; N Iraji Nasrabadi; R Derafshi
Journal:  J Dent (Shiraz)       Date:  2013-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.