Literature DB >> 18263682

Lung diffusing capacity for nitric oxide and carbon monoxide: dependence on breath-hold time.

Holger Dressel1, Laura Filser, Rainald Fischer, Dorothea de la Motte, Werner Steinhaeusser, Rudolf M Huber, Dennis Nowak, Rudolf A Jörres.   

Abstract

BACKGROUND: The combined measurement of diffusing capacity of the lung for nitric oxide (Dlno) and diffusing capacity of the lung for carbon monoxide (Dlco) is a simple, noninvasive tool, but methodologic factors might influence results and reproducibility. We thus quantified the influence of breath-hold time on Dlco and Dlno in subjects with or without airway disease.
METHODS: Simultaneous single-breath measurements of Dlco and Dlno were performed in 10 patients with cystic fibrosis (CF) [mean +/- SD age, 33 +/- 9 years; FEV(1), 69 +/- 28% of predicted] and 10 healthy subjects (age, 31 +/- 9 years; FEV(1), 108 +/- 8% of predicted), using the Masterscreen PFT (Viasys/Jaeger; Höchberg, Germany), with 45 ppm of inspired nitric oxide (NO), and breath-hold times of 4 s, 6 s, 8 s, and 10 s. The last two of three consecutive measurements were used for analysis.
RESULTS: In healthy subjects but not patients with CF, Dlno, and Dlco differed significantly (p < 0.05 each) between breath-hold times. Differences primarily occurred at 4 s and 10 s, while at 6 s and 8 s alveolar volume (VA), Dlno, Dlco, and Dlno/Dlco were similar. Variability of consecutive measurements (either three or the last two measurements) did not depend on breath-hold time. At 8 s, mean variabilities of Dlno and Dlco in healthy subjects were 4.9% and 2.5%, respectively, and 4.2% and 3.2% at 6 s. At 8 s, mean variabilities of Dlno and Dlco in CF patients were 4.4% and 1.9%, and 7.4% and 3.3% at 6 s.
CONCLUSIONS: Single-breath determinations of dlno and dlco showed no difference between breath-hold times of 6 s and 8 s in subjects with or without airway obstruction, and reproducibility was acceptable. Standardization of breath-hold time for Dlno measurements seems important for clinical and research comparisons.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18263682     DOI: 10.1378/chest.07-2388

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  11 in total

1.  Quantitative computed tomography detects interstitial lung diseases proven by biopsy.

Authors:  Alarico Ariani; Andrea Imperatori; Massimo Castiglioni; Elisa Daffrè; Marina Aiello; Giuseppina Bertorelli; Alfredo Chetta; Lorenzo Dominioni; Nicola Rotolo
Journal:  Sarcoidosis Vasc Diffuse Lung Dis       Date:  2018-04-28       Impact factor: 0.670

2.  The impact of pulmonary disease on noninvasive measurement of cardiac output by the inert gas rebreathing method.

Authors:  Joachim Saur; Frederik Trinkmann; Christina Doesch; Armin Scherhag; Joachim Brade; Stefan O Schoenberg; Martin Borggrefe; Jens J Kaden; Theano Papavassiliu
Journal:  Lung       Date:  2010-07-31       Impact factor: 2.584

3.  Automatic quantitative computed tomography measurement of longitudinal lung volume loss in interstitial lung diseases.

Authors:  Mouhamad Nasser; Marion Colevray; Salim A Si-Mohamed; Olivier Nempont; Pierre-Jean Lartaud; Anna Vlachomitrou; Thomas Broussaud; Kais Ahmad; Julie Traclet; Vincent Cottin; Loic Boussel
Journal:  Eur Radiol       Date:  2022-01-14       Impact factor: 7.034

4.  The single-breath diffusing capacity of CO and NO in healthy children of European descent.

Authors:  Astrid Thomas; Birgitte Hanel; Jacob L Marott; Frederik Buchvald; Jann Mortensen; Kim G Nielsen
Journal:  PLoS One       Date:  2014-12-16       Impact factor: 3.240

5.  Short halt in vaping modifies cardiorespiratory parameters and urine metabolome: a randomized trial.

Authors:  Martin Chaumont; Vanessa Tagliatti; El Mehdi Channan; Jean-Marie Colet; Alfred Bernard; Sofia Morra; Guillaume Deprez; Alain Van Muylem; Nadia Debbas; Thomas Schaefer; Vitalie Faoro; Philippe van de Borne
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2019-11-13       Impact factor: 5.464

6.  Lung diffusing capacity for nitric oxide and carbon monoxide in relation to morphological changes as assessed by computed tomography in patients with cystic fibrosis.

Authors:  Holger Dressel; Laura Filser; Rainald Fischer; Katharina Marten; Ullrich Müller-Lisse; Dorothea de la Motte; Dennis Nowak; Rudolf M Huber; Rudolf A Jörres
Journal:  BMC Pulm Med       Date:  2009-06-16       Impact factor: 3.317

7.  The need for race-specific reference equations for pulmonary diffusing capacity for nitric oxide.

Authors:  Gerald Stanley Zavorsky; Ahmad Saleh Almamary; Mobarak Khalid Alqahtani; Shi Huh Samuel Shan; Douglas Shawn Gardenhire
Journal:  BMC Pulm Med       Date:  2021-07-13       Impact factor: 3.317

8.  Exhaled breath condensate detects baseline reductions in chloride and increases in response to albuterol in cystic fibrosis patients.

Authors:  Courtney M Wheatley; Wayne J Morgan; Nicholas A Cassuto; William T Foxx-Lupo; Cori L Daines; Mary A Morgan; Hanna Phan; Eric M Snyder
Journal:  Clin Med Insights Circ Respir Pulm Med       Date:  2013-12-10

9.  Combined diffusing capacity for nitric oxide and carbon monoxide as predictor of bronchiolitis obliterans syndrome following lung transplantation.

Authors:  Anna Winkler; Kathrin Kahnert; Jürgen Behr; Claus Neurohr; Nikolaus Kneidinger; Rudolf Hatz; Holger Dressel; Thomas Radtke; Rudolf A Jörres
Journal:  Respir Res       Date:  2018-09-10

10.  12-Week Inspiratory Muscle Training Improves Respiratory Muscle Strength in Adult Patients with Stable Asthma: A Randomized Controlled Trial.

Authors:  Yi Chung; Ting-Yu Huang; Yi-Hung Liao; Yu-Chi Kuo
Journal:  Int J Environ Res Public Health       Date:  2021-03-22       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.