Literature DB >> 1825756

Ligation of the structures of the cystic pedicle during laparoscopic cholecystectomy.

L K Nathanson1, D W Easter, A Cuschieri.   

Abstract

Advances in optics, endotelevision monitoring, and instrumentation have led to the development of laparoscopic cholecystectomy. As in the open, standard operation, the crucial step is the dissection of the cystic pedicle containing the respective duct, artery, and lymph node. All the groups involved in laparoscopic cholecystectomy have to date opted for the use of applicators to clip the cystic duct and artery. As there are intrinsic disadvantages to the use of clips, we report an alternative method which involves ligation of these structures using the Roeder slip knot with dry chromic catgut. The safety margin of this knot was initially tested in vitro using a Instrom tensiometer. Under these experimental conditions, the Roeder slip knot tied with #0 dry chromic catgut ligature started to yield at 225 g. As the estimated tension on the cystic duct (1.1 g) and a 4-mm artery (6.0 g) in vivo is well below this figure, the safety of this knot with dry catgut in clinical practice is beyond question. The technique of Roeder slip-loop knotting was used to ligate the cystic artery and duct in a consecutive series of 80 patients undergoing laparoscopic cholecystectomy. This clinical experience has confirmed its safety and ease of execution. The particular advantages of Roeder loop ligation include execution through a 5.5-mm cannula and accurate placement of the knot. In addition, the technique requires less length of mobilized duct and artery, which is an important practical consideration in patients with a fibrosed gallbladder and shortened cystic pedicle.

Entities:  

Mesh:

Year:  1991        PMID: 1825756     DOI: 10.1016/0002-9610(91)90596-6

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  10 in total

1.  A novel ligation forceps can be used as a ligature carrier and knot pusher during laparoscopic surgery.

Authors:  T Asao; H Kuwano; E Mochiki; J Nakamura; H Shoji; T Shimura; K Fujita
Journal:  Surg Endosc       Date:  2001-04-03       Impact factor: 4.584

2.  Clipless cholecystectomy: which sealer should be used?

Authors:  Burak Kavlakoglu; Recep Pekcici; Suleyman Oral
Journal:  World J Surg       Date:  2011-04       Impact factor: 3.352

3.  An audit of cystic duct closure in laparoscopic cholecystectomies.

Authors:  A Rohatgi; A L Widdison
Journal:  Surg Endosc       Date:  2006-04-25       Impact factor: 4.584

4.  Comparative study between clipless laparoscopic cholecystectomy by harmonic scalpel versus conventional method: a prospective randomized study.

Authors:  Tharwat Kandil; Ayman El Nakeeb; Emad El Hefnawy
Journal:  J Gastrointest Surg       Date:  2009-10-31       Impact factor: 3.452

5.  Absorbable clips for cystic duct ligation in laparoscopic cholecystectomy.

Authors:  K L Leung; K H Kwong; W Y Lau; S C Chung; A K Li
Journal:  Surg Endosc       Date:  1996-01       Impact factor: 4.584

6.  Comparison of titanium and absorbable polymeric surgical clips for use in laparoscopic cholecystectomy.

Authors:  R D Klein; G Jessup; F Ahari; R J Connolly; S D Schwaitzberg
Journal:  Surg Endosc       Date:  1994-07       Impact factor: 4.584

7.  A simple technique for knot tying in single incision laparoscopic surgery (SILS).

Authors:  Baki Ekçi
Journal:  Clinics (Sao Paulo)       Date:  2010       Impact factor: 2.365

8.  Comparative study of the holding strength of slipknots using absorbable and nonabsorbable ligature materials.

Authors:  S M Shimi; M Lirici; G Vander Velpen; A Cuschieri
Journal:  Surg Endosc       Date:  1994-11       Impact factor: 4.584

9.  Laparoscopic cholecystectomy with Harmonic scalpel.

Authors:  Roberta Gelmini; Chiara Franzoni; Stefano Zona; Alessia Andreotti; Massimo Saviano
Journal:  JSLS       Date:  2010 Jan-Mar       Impact factor: 2.172

10.  Scissor-knot-pusher: an instrument for simplified laparoscopic extracorporeal knotting.

Authors:  Stefano Olmi; Enrico Croce
Journal:  JSLS       Date:  2003 Jul-Sep       Impact factor: 2.172

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.