Literature DB >> 18256455

Connection between RR-interval length and the pulsatile microcirculatory flow.

Hsin Hsiu1, Chia-Liang Hsu, Wen-Rei Chiang, Pin-Tsun Chao, Tse-Lin Hsu, Ming-Yie Jan, Wei-Kung Wang, Yuh-Ying Lin Wang.   

Abstract

The present study used laser Doppler flowmetry (LDF) to investigate the connection between skin microcirculatory flow and the length of the RR interval (LRR). Local heating was performed on healthy volunteers to further elucidate its effect on LDF index. ECG and LDF signals were measured in 102 trials on seven volunteers. Each experiment involved a 5 min control and a 5 min heating-effect sequence. Each laser Doppler flux pulse was categorized into four groups according to its LRR compared with the 5 min average LRR. Synchronized averaging analysis was applied to the four groups of pulses to obtain their averaged waveforms, from which four flux parameters were calculated. The ac component of the flux increased significantly with increasing LRR, and the differences therein between the groups with LRR more than 4% smaller and more than 4% larger than the average LRR increased from 15.8% during the control period to 23.9% during the heating period. Understanding of the different flux responses between the control and local-heating experiments may aid the development of a new index, which helps to avoid LDF's main drawback of providing only qualitative measurement.

Mesh:

Year:  2008        PMID: 18256455     DOI: 10.1088/0967-3334/29/2/007

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

1.  Effects of acupuncture at the Hoku acupoint on the pulsatile laser Doppler signal at the heartbeat frequency.

Authors:  Hsin Hsiu; Wei-Chen Hsu; Chia-Liang Hsu; Ming-Yie Jan; Yuh-Ying Wang-Lin
Journal:  Lasers Med Sci       Date:  2008-09-09       Impact factor: 3.161

2.  Spectral analysis of the microcirculatory laser Doppler signal at the Hoku acupuncture point.

Authors:  Hsin Hsiu; Wei-Chen Hsu; Shih-Ming Huang; Chia-Liang Hsu; Yuh-Ying Lin Wang
Journal:  Lasers Med Sci       Date:  2008-05-27       Impact factor: 3.161

3.  Assessing the effects of acupuncture by comparing needling the hegu acupoint and needling nearby nonacupoints by spectral analysis of microcirculatory laser Doppler signals.

Authors:  Hsin Hsiu; Wei-Chen Hsu; Chia-Liang Hsu; Shih-Min Huang
Journal:  Evid Based Complement Alternat Med       Date:  2011-06-16       Impact factor: 2.629