Literature DB >> 18255480

Feasibility of tomography with unknown view angles.

S Basu1, Y Bresler.   

Abstract

In the standard two-dimensional (2-D) parallel beam tomographic formulation, it is generally assumed that the angles at which the projections were acquired are known. We have previously demonstrated, however, that under fairly mild conditions these view angles can be uniquely recovered from the projections themselves. We address the question of reliability of such solutions to the angle recovery problem using moments of the projections. We demonstrate that under mild conditions, the angle recovery problem has unique solutions and is stable with respect to perturbations in the data. Furthermore, we determine the Cramer-Rao lower bounds on the variance of the estimates of the angles when the projection are corrupted by additive Gaussian noise. We also treat the case in which each projection is shifted by some unknown amount which must be jointly estimated with the view angles. Motivated by the stability results and relatively small values of the error bounds, we construct a simple algorithm to approximate the ML estimator and demonstrate that the problem can be feasibly solved in the presence of noise. Simulations using this simple estimator on a variety of phantoms show excellent performance at low to moderate noise levels, essentially achieving the Cramer-Rao bounds.

Year:  2000        PMID: 18255480     DOI: 10.1109/83.846252

Source DB:  PubMed          Journal:  IEEE Trans Image Process        ISSN: 1057-7149            Impact factor:   10.856


  6 in total

1.  Three-Dimensional Structure Determination from Common Lines in Cryo-EM by Eigenvectors and Semidefinite Programming().

Authors:  A Singer; Y Shkolnisky
Journal:  SIAM J Imaging Sci       Date:  2011-06-07       Impact factor: 2.867

2.  A look at . . . . Moment-based approaches in imaging part 4: Some applications.

Authors:  Huazhong Shu; Limin Luo; Jean-Louis Coatrieux
Journal:  IEEE Eng Med Biol Mag       Date:  2008 Sep-Oct

3.  Two-Dimensional Tomography from Noisy Projections Taken at Unknown Random Directions.

Authors:  A Singer; H-T Wu
Journal:  SIAM J Imaging Sci       Date:  2013-01-01       Impact factor: 2.867

4.  Viewing Angle Classification of Cryo-Electron Microscopy Images Using Eigenvectors.

Authors:  A Singer; Z Zhao; Y Shkolnisky; R Hadani
Journal:  SIAM J Imaging Sci       Date:  2011-06-23       Impact factor: 2.867

5.  Multiclass maximum-likelihood symmetry determination and motif reconstruction of 3-D helical objects from projection images for electron microscopy.

Authors:  Seunghee Lee; Peter C Doerschuk; John E Johnson
Journal:  IEEE Trans Image Process       Date:  2011-02-17       Impact factor: 10.856

6.  Estimating view parameters from random projections for Tomography using spherical MDS.

Authors:  Yi Fang; Sundar Murugappan; Karthik Ramani
Journal:  BMC Med Imaging       Date:  2010-06-18       Impact factor: 1.930

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.