Literature DB >> 18254667

CT virtual intravascular endoscopy in the visualization of fenestrated stent-grafts.

Zhonghua Sun1, Yvonne B Allen, Sanjay Nadkarni, Roslyn Knight, David E Hartley, Michael M D Lawrence-Brown.   

Abstract

PURPOSE: To report the diagnostic value of computed tomographic (CT) virtual intravascular endoscopy (VIE) in the assessment of patients with abdominal aortic aneurysm (AAA) treated with fenestrated endovascular grafts.
METHODS: Eight patients (7 men; mean age 76 years, range 70-82) with AAAs unsuitable for open surgery or conventional endovascular repair had fenestrated endovascular grafts implanted. Both pre- and post-fenestration multislice CT data were used to generate VIE images of the visceral artery ostia and the side branch fenestrated stents. CT VIE images were compared with conventional 2-dimensional (2D) axial CT and multiplanar reformatted (MPR) images for the ability to visualize the intraluminal appearance of stents, as well as to measure the length of stents that protruded into the aortic lumen.
RESULTS: Various fenestrations were deployed in 27 aortic branches. Scalloped and large fenestrations were implanted in 6 side branch ostia, respectively, and small fenestrations in 15 renal artery ostia. Fewer than half of the stents (37%) were found to be circular on VIE images, while the remaining stents were flared to varying extents at the inferior portion. The majority (96%) of stents protruded into the lumen up to 7.0 mm. Although the configuration of the side branch ostia changed to a variable extent, no significant difference was apparent between the diameters of branch ostia before and after fenestration (p>0.05).
CONCLUSION: Our preliminary study shows that VIE proved superior to conventional 2D or MPR images in visualizing the final configuration of the fenestrated vessels and was comparable to the other techniques in measuring stent protrusion into the aortic lumen. VIE could be a valuable technique to identify any suspected abnormalities associated with fenestrated endovascular grafts by demonstrating the final intraluminal configuration of the stents in the fenestrated vessels.

Entities:  

Mesh:

Year:  2008        PMID: 18254667     DOI: 10.1583/07-2234.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  15 in total

Review 1.  CT angiography in the diagnosis of cardiovascular disease: a transformation in cardiovascular CT practice.

Authors:  Zhonghua Sun; Mansour Al Moudi; Yan Cao
Journal:  Quant Imaging Med Surg       Date:  2014-10

Review 2.  Multislice computed tomography angiography in the diagnosis of cardiovascular disease: 3D visualizations.

Authors:  Zhonghua Sun
Journal:  Front Med       Date:  2011-10-02       Impact factor: 4.592

3.  Helical CT angiography of fenestrated stent grafting of abdominal aortic aneurysms.

Authors:  Z Sun
Journal:  Biomed Imaging Interv J       Date:  2009-04-01

4.  Multislice CT virtual intravascular endoscopy of aortic dissection: A pictorial essay.

Authors:  Zhonghua Sun; Yan Cao
Journal:  World J Radiol       Date:  2010-11-28

5.  Endovascular stent graft repair of abdominal aortic aneurysms: Current status and future directions.

Authors:  Zhonghua Sun
Journal:  World J Radiol       Date:  2009-12-31

6.  Multislice CT virtual intravascular endoscopy for assessing pulmonary embolisms: a pictorial review.

Authors:  Zhonghua Sun; Sultan Ayed Al Dosari; Curtise Ng; Ali al-Muntashari; Saud Almaliky
Journal:  Korean J Radiol       Date:  2010-02-22       Impact factor: 3.500

7.  Angiographic and artefact-free computed tomography imaging of experimental aneurysms embolised with hydrogel filaments.

Authors:  Mark R McCoy; Gregory M Cruise; Monika Killer
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

8.  Multislice CT angiography of fenestrated endovascular stent grafting for treating abdominal aortic aneurysms: a pictorial review of the 2D/3D visualizations.

Authors:  Zhonghua Sun; Bibombe P Mwipatayi; Yvonne B Allen; David E Hartley; Michael M Lawrence-Brown
Journal:  Korean J Radiol       Date:  2009-04-22       Impact factor: 3.500

9.  CT virtual endoscopy and 3D stereoscopic visualisation in the evaluation of coronary stenting.

Authors:  Z Sun
Journal:  Biomed Imaging Interv J       Date:  2009-10-01

10.  Fenestrated stent graft repair of abdominal aortic aneurysm: hemodynamic analysis of the effect of fenestrated stents on the renal arteries.

Authors:  Zhonghua Sun; Thanapong Chaichana
Journal:  Korean J Radiol       Date:  2009-12-28       Impact factor: 3.500

View more