Effect of long-term repeated deflections on fatigue of preloaded superelastic nickel-titanium archwires.

Cornelis A J M van Aken1, Prem Pallav, Cornelis J Kleverlaan, Reinder B Kuitert, Birte Prahl-Andersen, Albert J Feilzer.   

Abstract

INTRODUCTION: The aim of this in-vitro study was to investigate the changes in force delivery of superelastic nickel-titanium archwires used in combination with a self-ligating bracket system after dynamic fatigue-loading in a 3-bracket model under controlled temperature.
METHODS: Samples of 2 superelastic nickel-titanium (active austenitic) wires, a conventional nickel-titanium wire, and a stainless steel wire, all 0.014-in round, were divided into 2 groups: static deflection and dynamic deflection. The static specimens were under a constant deflection of 3.0 mm. The dynamic specimens had the same constant deflection of 3.0 mm but were subjected to additional repeated deflections of 0.5 mm, applied by a fatigue tester. The test situation simulates a patient's archwire under deflection and subjected to occlusal contact during 1, 100, 10,000, and 100,000 cycles. Fatigue changes were assessed with a 3-point bending test.
RESULTS: Type of wire, loading or unloading, and number of cycles as within-subject factors were statistically significantly different. No statistically significant difference between the test condition, static vs dynamic, was found. The repeated deflections of 0.5 mm were not enough to induce an extra effect of fatigue.
CONCLUSIONS: Occlusal forces transferred to a considerably deflected archwire, such as in the large malalignments in the early stages of orthodontic treatment, will have no fatigue effect on the unloading force of that archwire.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18249294     DOI: 10.1016/j.ajodo.2005.10.030

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  3 in total

1.  Force level of small diameter nickel-titanium orthodontic wires ligated with different methods.

Authors:  Rodrigo Hitoshi Higa; José Fernando Castanha Henriques; Guilherme Janson; Murilo Matias; Karina Maria Salvatore de Freitas; Fernanda Pinelli Henriques; Manoela Fávaro Francisconi
Journal:  Prog Orthod       Date:  2017-08-01       Impact factor: 2.750

2.  Evaluation of the force generated by gradual deflection of 0.016-inch NiTi and stainless steel orthodontic wires in self-ligating metallic and esthetic brackets.

Authors:  Manoela-Fávaro Francisconi; Guilherme Janson; José-Fernando-Castanha Henriques; Karina-Maria-Salvatore Freitas; Paulo-Afonso-Silveira Francisconi
Journal:  J Clin Exp Dent       Date:  2019-05-01

3.  Comparison of deflection forces of esthetic archwires combined with ceramic brackets.

Authors:  Murilo Matias; Marcos Roberto de Freitas; Karina Maria Salvatore de Freitas; Guilherme Janson; Rodrigo Hitoshi Higa; Manoela Fávaro Francisconi
Journal:  J Appl Oral Sci       Date:  2018-02-08       Impact factor: 2.698

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.