Literature DB >> 18249025

Radiation effects on bone architecture in mice and rats resulting from in vivo micro-computed tomography scanning.

R Josh Klinck1, Graeme M Campbell, Steven K Boyd.   

Abstract

Recently established techniques for performing in vivo micro-computed tomography (micro-CT) provide the capability of monitoring bone changes in a living animal at various points in time. However, radiation exposure from repeated micro-CT scans may have an effect on skeletal growth in normal or disease-model animals. The purpose of this study is to test a high resolution (approximately 10 microm) in vivo micro-CT protocol on mice and rats used for bone research to understand the impact of micro-CT radiation exposure on bone architecture. Ovariectomy (OVX) or sham-OVX surgery was performed on groups (n=6-8/group) of 12-week-old C3H/HeJ, C57BL/6J, and BALB/cByJ mice, and one strain of rat (Wistar, retired breeders). The right proximal tibiae were scanned at weekly intervals while the contralateral left limbs were not scanned until the endpoint of the protocol. Trabecular and cortical bone morphology was compared between radiated and non-radiated limbs at the endpoint to quantify the radiation effect. No effects of radiation were observed in OVX or sham rats. Lower trabecular bone volume was observed in the radiated limbs (-8 to -20% relative to non-radiated limb) of all mice groups except sham BALB/cByJ mice and normal control C57BL/6J mice, however, the observed effects were much less than the observed effects of ovariectomy ( approximately 40-50% total bone volume reduction, depending on mouse strain), and no interactions between radiation and OVX treatment were observed (p>0.2). Using an internal non-radiated control within each animal is a potential method to elucidate the effect of radiation exposure for any in vivo protocol. Thus, although in vivo micro-CT is a valuable tool for bone-related research, the impact of radiation in skeletally immature mice should be considered, particularly for strains with low bone volume at the measured site.

Entities:  

Mesh:

Year:  2008        PMID: 18249025     DOI: 10.1016/j.medengphy.2007.11.004

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  54 in total

1.  Multiple exposures to unloading decrease bone's responsivity but compound skeletal losses in C57BL/6 mice.

Authors:  Shikha Gupta; Surabhi Vijayaraghavan; Gunes Uzer; Stefan Judex
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2012-05-16       Impact factor: 3.619

2.  In vivo monitoring of bone microstructure by propagation-based phase-contrast computed tomography using monochromatic synchrotron light.

Authors:  Takeshi Matsumoto; Ryota Shimizu; Kentaro Uesugi
Journal:  Lab Invest       Date:  2019-10-22       Impact factor: 5.662

3.  Bone quality is partially recovered after the discontinuation of RANKL administration in rats by increased bone mass on existing trabeculae: an in vivo micro-CT study.

Authors:  Graeme M Campbell; Michael S Ominsky; Steven K Boyd
Journal:  Osteoporos Int       Date:  2010-05-18       Impact factor: 4.507

4.  Quantitative analysis of bone and soft tissue by micro-computed tomography: applications to ex vivo and in vivo studies.

Authors:  Graeme M Campbell; Antonia Sophocleous
Journal:  Bonekey Rep       Date:  2014-08-20

5.  Soft-tissue spectral subtraction improves transcutaneous Raman estimates of murine bone strength in vivo.

Authors:  Keren Chen; Christine Massie; Andrew J Berger
Journal:  J Biophotonics       Date:  2020-08-31       Impact factor: 3.207

6.  Repeated irradiation from micro-computed tomography scanning at 2, 4 and 6 months of age does not induce damage to tibial bone microstructure in male and female CD-1 mice.

Authors:  Sandra M Sacco; Caitlin Saint; Amanda B Longo; Charles B Wakefield; Phil L Salmon; Paul J LeBlanc; Wendy E Ward
Journal:  Bonekey Rep       Date:  2017-01-13

7.  Pulmonary abnormalities in mice with paracoccidioidomycosis: a sequential study comparing high resolution computed tomography and pathologic findings.

Authors:  Damaris Lopera; Tonny Naranjo; José Miguel Hidalgo; Bernardo Miguel de Oliveira Pascarelli; Jairo Hernando Patiño; Henrique Leonel Lenzi; Angela Restrepo; Luz Elena Cano
Journal:  PLoS Negl Trop Dis       Date:  2010-06-29

8.  Low-level vibrations retain bone marrow's osteogenic potential and augment recovery of trabecular bone during reambulation.

Authors:  Engin Ozcivici; Yen K Luu; Clinton T Rubin; Stefan Judex
Journal:  PLoS One       Date:  2010-06-17       Impact factor: 3.240

9.  Quantification of skeletal growth, modeling, and remodeling by in vivo micro computed tomography.

Authors:  Allison R Altman; Wei-Ju Tseng; Chantal M J de Bakker; Abhishek Chandra; Shenghui Lan; Beom Kang Huh; Shiming Luo; Mary B Leonard; Ling Qin; X Sherry Liu
Journal:  Bone       Date:  2015-08-06       Impact factor: 4.398

10.  The influence of therapeutic radiation on the patterns of bone remodeling in ovary-intact and ovariectomized mice.

Authors:  Susanta K Hui; Gregory R Fairchild; Louis S Kidder; Manju Sharma; Maryka Bhattacharya; Scott Jackson; Chap Le; Anna Petryk; Mohammad Saiful Islam; Douglas Yee
Journal:  Calcif Tissue Int       Date:  2013-01-12       Impact factor: 4.333

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.