Literature DB >> 18248568

Postoperative blood loss and transfusion associated with use of Hextend in cardiac surgery patients at a blood conservation center.

David M Moskowitz1, Aryeh Shander, Mazyar Javidroozi, James J Klein, Seth I Perelman, Jeffrey Nemeth, M Arisan Ergin.   

Abstract

BACKGROUND: Hydroxyethyl starch (HES) solutions are readily available colloids, but their widespread use is shadowed by controversies surrounding their effects on bleeding. This retrospective study was conducted to evaluate the relationship between Hextend (HEX; Hospira, Inc.) doses of 1 to 20 mL/kg and allogeneic transfusion and 24-hour chest tube drainage (CTD) in cardiac surgeries at a blood conservation center. STUDY DESIGN AND METHODS: After institutional review board approval, data on 748 patients undergoing coronary artery bypass grafting (CABG), valve, or combined CABG and valve surgeries were collected. Cases not receiving HEX (due to contraindications, e.g., renal failure, bleeding diathesis) or receiving more than 20 mL per kg HEX, not accepting transfusions, or requiring more extensive surgery were excluded, and the remaining 621 cases were analyzed.
RESULTS: Overall transfusion rate and mean CTD were 12.7 percent and 460.4 mL, respectively. Patients who received transfusions received more HEX (10.8 mL/kg vs. 9.8 mL/kg; p = 0.043) but HEX per kg was not associated with higher transfusion rates in multivariate analysis (p = 0.077). HEX per kg was associated with CTD in both uni- and multivariate analyzes (p < 0.001) with 1.66 percent increase in CTD for every 1 mL per kg increase in HEX.
CONCLUSIONS: Although HEX was associated with transfusion in univariate analysis and with CTD in uni- and multivariate analysis, the former was no longer significant when adjusted for other predictors of transfusion in our selected patient population at a blood conservation center. The clinical significance of the observed increase in CTD remains undetermined. To minimize transfusion and bleeding in these patients, it is recommended that HEX be used in amounts of not more than 20 mL per kg together with point-of-care coagulation tests and other blood conservation strategies.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18248568     DOI: 10.1111/j.1537-2995.2007.01627.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  4 in total

1.  Clinical evaluation of a novel system for monitoring surgical hemoglobin loss.

Authors:  Allen A Holmes; Gerhardt Konig; Vicki Ting; Bridget Philip; Thomas Puzio; Siddarth Satish; Jonathan H Waters
Journal:  Anesth Analg       Date:  2014-09       Impact factor: 5.108

2.  Consensus statement of the ESICM task force on colloid volume therapy in critically ill patients.

Authors:  Konrad Reinhart; Anders Perner; Charles L Sprung; Roman Jaeschke; Frederique Schortgen; A B Johan Groeneveld; Richard Beale; Christiane S Hartog
Journal:  Intensive Care Med       Date:  2012-02-10       Impact factor: 17.440

3.  In vitro evaluation of a novel system for monitoring surgical hemoglobin loss.

Authors:  Gerhardt Konig; Allen A Holmes; Rosario Garcia; Julianne M Mendoza; Mazyar Javidroozi; Siddarth Satish; Jonathan H Waters
Journal:  Anesth Analg       Date:  2014-09       Impact factor: 5.108

Review 4.  Coagulation complications following trauma.

Authors:  Wenjun Z Martini
Journal:  Mil Med Res       Date:  2016-11-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.