Walking after incomplete spinal cord injury using an implanted FES system: a case report.

Elizabeth Hardin1, Rudi Kobetic, Lori Murray, Michelle Corado-Ahmed, Gilles Pinault, Jonathan Sakai, Stephanie Nogan Bailey, Chester Ho, Ronald J Triolo.   

Abstract

Implanted functional electrical stimulation (FES) systems for walking are experimentally available to individuals with incomplete spinal cord injury (SCI); however, data on short-term therapeutic and functional outcomes are limited. The goal of this study was to quantify therapeutic and functional effects of an implanted FES system for walking after incomplete cervical SCI. After robotic-assisted treadmill training and overground gait training maximized his voluntary function, an individual with incomplete SCI (American Spinal Injury Association grade C, cervical level 6-7) who could stand volitionally but not step was surgically implanted with an 8-channel receiver stimulator and intramuscular electrodes. Electrodes were implanted bilaterally, recruiting iliopsoas, vastus intermedius and lateralis, tensor fasciae latae, tibialis anterior, and peroneus longus muscles. Twelve weeks of training followed limited activity post-surgery. Customized stimulation patterns addressed gait deficits via an external control unit. The system was well-tolerated and reliable. After the 12-week training, maximal walking distance increased (from 14 m to 309 m), maximal walking speed was 10 times greater (from 0.02 m/s to 0.20 m/s), and physiological cost index was 5 times less (from 44.4 beats/m to 8.6 beats/m). Voluntary locomotor function was unchanged. The implanted FES system was well-tolerated, reliable, and supplemented function, allowing the participant limited community ambulation. Physiological effort decreased and maximal walking distance increased dramatically over 12 weeks.

Entities:  

Mesh:

Year:  2007        PMID: 18247230     DOI: 10.1682/jrrd.2007.03.0333

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  19 in total

Review 1.  The influence of orthosis options on walking parameters in spinal cord-injured patients: a literature review.

Authors:  M Arazpour; M Samadian; K Ebrahimzadeh; M Ahmadi Bani; S W Hutchins
Journal:  Spinal Cord       Date:  2016-02-09       Impact factor: 2.772

Review 2.  Functional electrical stimulation and spinal cord injury.

Authors:  Chester H Ho; Ronald J Triolo; Anastasia L Elias; Kevin L Kilgore; Anthony F DiMarco; Kath Bogie; Albert H Vette; Musa L Audu; Rudi Kobetic; Sarah R Chang; K Ming Chan; Sean Dukelow; Dennis J Bourbeau; Steven W Brose; Kenneth J Gustafson; Zelma H T Kiss; Vivian K Mushahwar
Journal:  Phys Med Rehabil Clin N Am       Date:  2014-08       Impact factor: 1.784

3.  Model-Based Dynamic Control Allocation in a Hybrid Neuroprosthesis.

Authors:  Nicholas A Kirsch; Xuefeng Bao; Naji A Alibeji; Brad E Dicianno; Nitin Sharma
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2017-09-22       Impact factor: 3.802

Review 4.  The efficiency of orthotic interventions on energy consumption in paraplegic patients: a literature review.

Authors:  M Arazpour; M Samadian; M Bahramizadeh; M Joghtaei; M Maleki; M Ahmadi Bani; S W Hutchins
Journal:  Spinal Cord       Date:  2015-01-20       Impact factor: 2.772

5.  Impact of an implanted neuroprosthesis on community ambulation in incomplete SCI.

Authors:  Lisa M Lombardo; Rudolf Kobetic; Gilles Pinault; Kevin M Foglyano; Stephanie N Bailey; Stephen Selkirk; Ronald J Triolo
Journal:  J Spinal Cord Med       Date:  2017-02-03       Impact factor: 1.985

6.  A preliminary comparison of myoelectric and cyclic control of an implanted neuroprosthesis to modulate gait speed in incomplete SCI.

Authors:  Lisa M Lombardo; Stephanie N Bailey; Kevin M Foglyano; Michael E Miller; Gilles Pinault; Ronald J Triolo
Journal:  J Spinal Cord Med       Date:  2014-09-22       Impact factor: 1.985

7.  The design of and chronic tissue response to a composite nerve electrode with patterned stiffness.

Authors:  M J Freeberg; M A Stone; R J Triolo; D J Tyler
Journal:  J Neural Eng       Date:  2017-03-13       Impact factor: 5.379

8.  Walking after incomplete spinal cord injury with an implanted neuromuscular electrical stimulation system and a hinged knee replacement: a single-subject study.

Authors:  Nathaniel S Makowski; Lisa M Lombardo; Kevin M Foglyano; Rudi Kobetic; Gilles Pinault; Stephen M Selkirk; Ronald J Triolo
Journal:  Spinal Cord Ser Cases       Date:  2020-09-15

9.  Intraoperative Responses May Predict Chronic Performance of Composite Flat Interface Nerve Electrodes on Human Femoral Nerves.

Authors:  Max J Freeberg; Rahila Ansari; Gilles C J Pinault; Lisa M Lombardo; Michael E Miller; Dustin J Tyler; Ronald J Triolo
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2019-11-04       Impact factor: 4.528

10.  Long-Term Performance and User Satisfaction With Implanted Neuroprostheses for Upright Mobility After Paraplegia: 2- to 14-Year Follow-Up.

Authors:  Ronald J Triolo; Stephanie Nogan Bailey; Kevin M Foglyano; Rudi Kobetic; Lisa M Lombardo; Michael E Miller; Gilles Pinault
Journal:  Arch Phys Med Rehabil       Date:  2017-09-09       Impact factor: 4.060

View more