Literature DB >> 18244263

Adaptive multi-element synthetic aperture imaging with motion and phase aberration correction.

M Karaman1, H S Bilge, M O'Donnell.   

Abstract

Multi-element synthetic aperture techniques employing subaperture processing over successive firing steps can produce good image quality with simple front-end hardware but are susceptible to motion and phase aberration artifacts. We explore correlation processing using fully common spatial frequencies of overlapping subapertures to adapt beamforming for motion and phase aberrations. Signals derived from the subset of elements representing common spatial frequencies exhibit significantly higher correlation coefficients than those from signals computed using the entire subaperture. In addition, the correlation coefficient decreases linearly with subaperture separation for complete subaperture signals, but remains nearly constant with subaperture separation if only common spatial frequencies are used. Adaptive multi-element synthetic aperture imaging with correlation processing using fully common spatial frequencies is tested on experimental RF data acquired from a diffuse scattering phantom using a 3.5 MHz, 128-element transducer array. The results indicate that common spatial frequencies can be used efficiently for correlation processing to correct motion and phase aberration for adaptive multi-element synthetic aperture imaging.

Year:  1998        PMID: 18244263     DOI: 10.1109/58.710591

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  6 in total

1.  2-D array for 3-D ultrasound imaging using synthetic aperture techniques.

Authors:  Nadim M Daher; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-05       Impact factor: 2.725

2.  Extending Retrospective Encoding for Robust Recovery of the Multistatic Data Set.

Authors:  Rehman Ali; Carl D Herickhoff; Dongwoon Hyun; Jeremy J Dahl; Nick Bottenus
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-12-23       Impact factor: 2.725

3.  Effects of line fiducial parameters and beamforming on ultrasound calibration.

Authors:  Golafsoun Ameri; John S H Baxter; A Jonathan McLeod; Terry M Peters; Elvis C S Chen
Journal:  J Med Imaging (Bellingham)       Date:  2017-02-28

4.  Effects of motion on correlations of pulse-echo ultrasound signals: Applications in delay estimation and aperture coherence.

Authors:  Dongwoon Hyun; Jeremy J Dahl
Journal:  J Acoust Soc Am       Date:  2020-03       Impact factor: 1.840

5.  Recovery of the Complete Data Set From Focused Transmit Beams.

Authors:  Nick Bottenus
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-01       Impact factor: 2.725

6.  Synthetic Aperture Imaging Using High-Frequency Convex Array for Ophthalmic Ultrasound Applications.

Authors:  Hae Gyun Lim; Hyung Ham Kim; Changhan Yoon
Journal:  Sensors (Basel)       Date:  2021-03-24       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.