Literature DB >> 18244247

Microcalcifications as elastic scatterers under ultrasound.

M E Anderson1, M C Soo, G E Trahey.   

Abstract

One of the fundamental limitations of medical ultrasound in the imaging of the breast is the inability of current practice to reliably visualize microcalcifications in the size range of clinical interest. Microcalcifications (MCs) are small crystals of calcium phosphates that form in human tissue through a number of mechanisms. The size, morphology, and distribution of MCs are important indicators in the mammographic screening for and diagnosis of various carcinomas in the breast. The authors are investigating the imaging of MCs under ultrasound in the interest of extending the utility of medical ultrasound in the breast clinic. They present an analysis of the acoustic properties of MCs modeled as elastic spheres based on the Faran model that considers the predicted complex spectra and spatial coherence of echoes from MCs. They have found the predictions of the model to be similar to ultrasound echoes from suspected MCs in vivo. They also present breast phase aberration estimates and spatial and frequency compounding results based on the echoes from these targets.

Entities:  

Year:  1998        PMID: 18244247     DOI: 10.1109/58.710559

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  7 in total

1.  Frequency dependence of ultrasonic backscatter from human trabecular bone: theory and experiment.

Authors:  K A Wear
Journal:  J Acoust Soc Am       Date:  1999-12       Impact factor: 1.840

2.  The effect of trabecular material properties on the frequency dependence of backscatter from cancellous bone.

Authors:  Keith A Wear
Journal:  J Acoust Soc Am       Date:  2003-07       Impact factor: 1.840

3.  The dependence of ultrasonic backscatter on trabecular thickness in human calcaneus: theoretical and experimental results.

Authors:  Keith A Wear; Andres Laib
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-08       Impact factor: 2.725

Review 4.  Ultrasonic scattering from cancellous bone: a review.

Authors:  K A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-07       Impact factor: 2.725

5.  Dominant factor analysis of B-flow twinkling sign with phantom and simulation data.

Authors:  Weijia Lu; Bruno Haider
Journal:  J Med Ultrason (2001)       Date:  2016-09-29       Impact factor: 1.314

Review 6.  Spatial Coherence in Medical Ultrasound: A Review.

Authors:  James Long; Gregg Trahey; Nick Bottenus
Journal:  Ultrasound Med Biol       Date:  2022-03-11       Impact factor: 3.694

7.  H-scan analysis of thyroid lesions.

Authors:  Gary R Ge; Rosa Laimes; Joseph Pinto; Jorge Guerrero; Himelda Chavez; Claudia Salazar; Roberto J Lavarello; Kevin J Parker
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.