Experimental study of high frame rate imaging with limited diffraction beams.

J Y Lu1.   

Abstract

Limited diffraction beams have a large depth of field and have many potential applications. Recently, a new method (Fourier method) was developed with limited diffraction beams for image construction. With the method and a single plane wave transmission, both 2D (two-dimensional) and 3D (three-dimensional) images of a very high frame rate (up to 3750 frames/s for a depth of 200 mm in biological soft tissues) and a high signal-to-noise ratio (SNR) can be constructed with relatively simple and inexpensive hardware. If limited diffraction beams of different parameters are used in both transmission and reception and transducer aperture is shaded with a cosine function, high-resolution and low-sidelobe images can be constructed with the new method without montage of multiple frames of images [the image quality is comparable to that obtained with a transmit-receive (two-way) dynamically focused imaging system]. In this paper, the Fourier method was studied with both experiment and computer simulation for 2D B-mode imaging. In the experiment, two commercial broadband 1D array transducers (48 and 64 elements) of different aperture sizes (18.288 and 38.4 mm) and center frequencies (2.25 and 2.5 MHz) were used to construct images of different viewing sizes. An ATS539 tissue-equivalent phantom of an average frequency-dependent attenuation of 0.5 dB/MHz/cm was used as a test object. To obtain high frame rate images, a single plane wave pulse (broadband) was transmitted with the arrays. Echoes received with the arrays were processed with both the Fourier and conventional dynamic focusing (delay-and-sum) methods to construct 2D B-mode images. Results show that the quality (resolution and contrast) of constructed images is virtually identical for both methods, except that the Fourier method is simpler to implement. Both methods have also a similar sensitivity to phase aberration distortions. Excellent agreement among theory, simulation, and experiment was obtained.

Year:  1998        PMID: 18244161     DOI: 10.1109/58.646914

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  8 in total

1.  Stolt's f-k migration for plane wave ultrasound imaging.

Authors:  Damien Garcia; Louis Le Tarnec; Stéphan Muth; Emmanuel Montagnon; Jonathan Porée; Guy Cloutier
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

2.  Photoacoustic clutter reduction by inversion of a linear scatter model using plane wave ultrasound measurements.

Authors:  Hans-Martin Schwab; Martin F Beckmann; Georg Schmitz
Journal:  Biomed Opt Express       Date:  2016-03-24       Impact factor: 3.732

3.  High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming.

Authors:  Hideyuki Hasegawa; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2011-05-07       Impact factor: 1.314

4.  Phase Modulation Beamforming for Ultrafast Plane-Wave Imaging.

Authors:  Bowen Jing; Brooks D Lindsey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-05-11       Impact factor: 2.725

5.  Application of X-Y separable 2-D array beamforming for increased frame rate and energy efficiency in handheld devices.

Authors:  Kevin Owen; Michael Fuller; John Hossack
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-07       Impact factor: 2.725

6.  Ultrasound Open Platforms for Next-Generation Imaging Technique Development.

Authors:  Enrico Boni; Alfred C H Yu; Steven Freear; Jorgen Arendt Jensen; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07       Impact factor: 2.725

7.  A submatrix spatial coherence approach to minimum variance beamforming combined with sign coherence factor for coherent plane wave compounding.

Authors:  Xin Yan; Yuanyuan Wang
Journal:  Technol Health Care       Date:  2022       Impact factor: 1.205

8.  Effects of Non-Elevation-Focalized Linear Array Transducer on Ultrasound Plane-Wave Imaging.

Authors:  Congzhi Wang; Yang Xiao; Jingjing Xia; Weibao Qiu; Hairong Zheng
Journal:  Sensors (Basel)       Date:  2016-11-12       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.