Literature DB >> 18243953

Constrained iterative reconstruction by the conjugate gradient method.

S Kawata, O Nalcioglu.   

Abstract

The conjugate gradient method incorporating the object-extent constraint is applied to image reconstruction of a three-dimensional object using an incomplete projection-data set. The missing information is recovered by constraining the solution with the knowledge of the outer boundary of the object-extent which may be a priori measured or known. The algorithm is derived from the least-squares criterion as an advanced version of conventional iterative reconstruction algorithms such as SIRT (Simultaneous Iterative Reconstruction Technique) and ILST (Iterative Least Squares Technique). In the case of reconstruction from noisy projection data, a method based on the minimum mean-square error criterion is also proposed. Computer simulated reconstruction images of a phantom using limited angle and number of views are presented. The result shows that the conjugate gradient method incorporating the object-extent constraining provides the fastest convergence and the least error.

Year:  1985        PMID: 18243953     DOI: 10.1109/TMI.1985.4307698

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  A new iterative reconstruction technique for attenuation correction in high-resolution positron emission tomography.

Authors:  K Knesaurek; J Machac; S Vallabhajosula; M S Buchsbaum
Journal:  Eur J Nucl Med       Date:  1996-06

2.  Undersampling patterns in k-space for compressed sensing MRI using two-dimensional Cartesian sampling.

Authors:  Shinya Kojima; Hiroyuki Shinohara; Takeyuki Hashimoto; Shigeru Suzuki
Journal:  Radiol Phys Technol       Date:  2018-08-04

3.  Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms.

Authors:  Jie Tang; Brian E Nett; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2009-09-09       Impact factor: 3.609

4.  Forward-Projection Architecture for Fast Iterative Image Reconstruction in X-ray CT.

Authors:  Jung Kuk Kim; Jeffrey A Fessler; Zhengya Zhang
Journal:  IEEE Trans Signal Process       Date:  2012-10       Impact factor: 4.931

5.  Spatially variant regularization for tissue strain measurement and shear modulus reconstruction.

Authors:  Chikayoshi Sumi
Journal:  J Med Ultrason (2001)       Date:  2007-09-14       Impact factor: 1.878

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.