| Literature DB >> 18243880 |
Jesús Tamarit-López1, Sergi Morais, Rosa Puchades, Angel Maquieira.
Abstract
The analytical potential of polystyrene (PS) spin-coated modified compact discs (CDs) surface as platforms for the development of microarray immunoassays is presented. The surface maintained the optical characteristics of compact discs, obtaining a transparent and smooth film polymer of 70 nm thickness, the track being read (lambda 780 nm) without errors in a commercial CD reader/writer. The analytical capability of the methodology was demonstrated through an analysis of a neurotoxic compound (2560 spots per disc), reaching 0.08 microg L(-1) as limit of detection. These figures demonstrate the enormous potential of using PS spin-coated compact discs in combination with CD players as an easy-to-operate and portable device to develop lab-on-a-disc analytical applications.Entities:
Mesh:
Substances:
Year: 2008 PMID: 18243880 DOI: 10.1016/j.aca.2007.12.028
Source DB: PubMed Journal: Anal Chim Acta ISSN: 0003-2670 Impact factor: 6.558