Literature DB >> 1824312

Indoor climate, air pollution, and human comfort.

L Mølhave1.   

Abstract

The term sick building syndrome (SBS) is frequently used to describe a set of symptoms often reported by occupants of certain buildings. The symptoms are supposed to be direct or indirect consequences of an inadequate indoor climate. Typically, a majority of the occupants in these buildings complain, and the most frequent complaint is irritation of eyes, nose, and throat. Many different factors are known to be potential agents for the symptoms and no definitive causality has been identified yet. In consequence authors of publications on indoor air quality have been using the SBS term in different ways. A review of literature indicates that in supposed "sick buildings" only the prevalence of irritation of mucosal membranes and headaches seems to differ significantly from the prevalence in buildings considered to have a normal indoor climate. Volatile organic compounds (VOC) are known to have a potency to cause symptoms like those included in SBS. A dose-response relation for sensory reactions and mucosal irritation caused by volatile organic air pollutants is discussed, and a tentative guideline at 3 mg/m3 (about 0.9 PPM toluene equivalent) for the total volatile organic compounds (TVOC) is suggested for the nonindustrial indoor climates.

Entities:  

Mesh:

Year:  1991        PMID: 1824312

Source DB:  PubMed          Journal:  J Expo Anal Environ Epidemiol        ISSN: 1053-4245


  5 in total

1.  Proteome changes in human bronchoalveolar cells following styrene exposure indicate involvement of oxidative stress in the molecular-response mechanism.

Authors:  Nora Mörbt; Iljana Mögel; Stefan Kalkhof; Ralph Feltens; Carmen Röder-Stolinski; Jiang Zheng; Carsten Vogt; Irina Lehmann; Martin von Bergen
Journal:  Proteomics       Date:  2009-11       Impact factor: 3.984

Review 2.  Hazardous air pollutants and asthma.

Authors:  George D Leikauf
Journal:  Environ Health Perspect       Date:  2002-08       Impact factor: 9.031

3.  Volatile Organic Compounds Sensing Using Optical Fibre Long Period Grating with Mesoporous Nano-Scale Coating.

Authors:  Jiri Hromadka; Sergiy Korposh; Matthew Partridge; Stephen W James; Frank Davis; Derrick Crump; Ralph P Tatam
Journal:  Sensors (Basel)       Date:  2017-02-08       Impact factor: 3.576

Review 4.  Phylloremediation of Air Pollutants: Exploiting the Potential of Plant Leaves and Leaf-Associated Microbes.

Authors:  Xiangying Wei; Shiheng Lyu; Ying Yu; Zonghua Wang; Hong Liu; Dongming Pan; Jianjun Chen
Journal:  Front Plant Sci       Date:  2017-07-28       Impact factor: 5.753

Review 5.  Evaluation of a possible association of urban air toxics and asthma.

Authors:  G D Leikauf; S Kline; R E Albert; C S Baxter; D I Bernstein; J Bernstein; C R Buncher
Journal:  Environ Health Perspect       Date:  1995-09       Impact factor: 9.031

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.