Literature DB >> 18241743

International controlled clinical trial of thoracic endovascular aneurysm repair with the Zenith TX2 endovascular graft: 1-year results.

Jon S Matsumura1, Richard P Cambria, Michael D Dake, Randy D Moore, Lars G Svensson, Scott Snyder.   

Abstract

PURPOSE: This trial evaluated the safety and effectiveness of thoracic endovascular aortic repair (TEVAR) with a contemporary endograft system compared with open surgical repair (open) of descending thoracic aortic aneurysms and large ulcers.
METHODS: Forty-two international trial sites enrolled 230 subjects with descending thoracic aortic aneurysms or ulcers. The study compared 160 TEVAR subjects treated with the Zenith TX2 Endovascular Graft (William Cook Europe, ApS, Bjaeverskov, Denmark) with 70 open subjects. Subjects were evaluated preprocedure, predischarge, 1, 6, and 12 months, and yearly through 5 years with medical examination, laboratory testing, chest radiographs, and computed tomography scans. Mortality rates, prespecified severe morbidity composite index, major morbidity, clinical utility, aneurysm rupture, and secondary interventions were compared. The TEVAR subjects were evaluated by a core laboratory for device performance, including change in aneurysm size, endoleak, migration, and device integrity.
RESULTS: The 30-day survival rate was noninferior (P < .01) for the TEVAR group compared with the open group (98.1% vs 94.3%). The severe morbidity composite index was lower for TEVAR (0.2 +/- 0.7 vs 0.7 +/- 1.2; P < .01). Cumulative major morbidity scores were significantly lower at 30 days for the TEVAR group compared with the open group (1.3 +/- 3.0 vs 2.9 +/- 3.6, P < .01). The TEVAR patients had fewer cardiovascular, pulmonary, and vascular adverse events, although neurologic events were not significantly different. Clinical utility for the TEVAR patients was superior to that of the open patients. No ruptures or conversions occurred in the first year. Reintervention rates were similar in both groups. At 12 months, aneurysm growth was identified in 7.1% (8/112), endoleak in 3.9% (4/103), migration (>10 mm) in 2.8% (3/107), and other device issues were rare. None of the patients with migration experienced endoleak, aneurysm growth, or required a secondary intervention.
CONCLUSIONS: Thoracic endovascular aortic repair with the TX2 is a safer and effective alternative to open surgical repair for the treatment of anatomically suitable descending thoracic aortic aneurysms and ulcers at 1 year of follow-up. Device performance issues are infrequent, but careful planning and regular follow-up with imaging remain a necessity.

Entities:  

Mesh:

Year:  2008        PMID: 18241743     DOI: 10.1016/j.jvs.2007.10.032

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  42 in total

1.  Endovascular therapy for thoracic aortic aneurysms: state of the art in 2012.

Authors:  Nicolas A Brozzi; Eric E Roselli
Journal:  Curr Treat Options Cardiovasc Med       Date:  2012-04

Review 2.  TEVAR: Endovascular Repair of the Thoracic Aorta.

Authors:  David A Nation; Grace J Wang
Journal:  Semin Intervent Radiol       Date:  2015-09       Impact factor: 1.513

Review 3.  Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management.

Authors:  Dania Daye; T Gregory Walker
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

4.  Magnitude and direction of pulsatile displacement forces acting on thoracic aortic endografts.

Authors:  C Alberto Figueroa; Charles A Taylor; Allen J Chiou; Victoria Yeh; Christopher K Zarins
Journal:  J Endovasc Ther       Date:  2009-06       Impact factor: 3.487

5.  Complications of endovascular aortic repair: prevention and management.

Authors:  Mark A Farber
Journal:  Tex Heart Inst J       Date:  2009

6.  Endovascular repair of the thoracic aorta.

Authors:  Grace J Wang; Ronald M Fairman
Journal:  Semin Intervent Radiol       Date:  2009-03       Impact factor: 1.513

7.  Computational analysis of stresses acting on intermodular junctions in thoracic aortic endografts.

Authors:  Anamika Prasad; Lillian K To; Madhu L Gorrepati; Christopher K Zarins; C Alberto Figueroa
Journal:  J Endovasc Ther       Date:  2011-08       Impact factor: 3.487

Review 8.  Debranching aortic surgery.

Authors:  Manuel Alonso Pérez; José Manuel Llaneza Coto; José Antonio Del Castro Madrazo; Carlota Fernández Prendes; Mario González Gay; Amer Zanabili Al-Sibbai
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

Review 9.  Postoperative imaging of the aorta.

Authors:  Weier Li; Sasiprapa Rongthong; Anand M Prabhakar; Sandeep Hedgire
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

Review 10.  Indications for Thoracic EndoVascular Aortic Repair (TEVAR): A Brief Review.

Authors:  Frank Manetta; Joshua Newman; Allan Mattia
Journal:  Int J Angiol       Date:  2018-08-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.