Marginal adaptation of all-ceramic crowns on implant abutments.

Wael Att1, Tomas Hoischen, Thomas Gerds, Jörg Rudolf Strub.   

Abstract

BACKGROUND: Studies focusing on the marginal accuracy of all-ceramic crowns on implant abutments are in short supply.
PURPOSE: This study evaluated the marginal accuracy of all-ceramic crowns on different implant abutments.
MATERIALS AND METHODS: Ninety-six standardized maxillary central incisor crowns (48 alumina and 48 zirconia) were fabricated for each of the six test groups (n = 16) (Ti1, titanium abutments-alumina crowns; Ti2, titanium abutments-zirconia crowns; Al1, alumina abutments-alumina crowns; Al2, alumina abutments-zirconia crowns; Zr1, zirconia abutments-alumina crowns; Zr2, zirconia abutments-zirconia crowns). The crowns were adhesively luted using a resin luting agent. The marginal gaps were examined on epoxy replicas before and after luting as well as after masticatory simulation at 200x magnification.
RESULTS: The geometrical mean (95% confidence limits) marginal gap values before cementation, after cementation, and after masticatory simulation were group Ti1: 39(37-42), 57(53-62), and 49(46-53); group Ti2: 43(40-47), 71(67-76), and 64(59-69); group Al1: 57(54-61), 87(85-90), and 67(65-69); group Al2: 66(63-69), 96(90-101), and 75(72-78); group Zr1: 54(51-57), 79(76-82), and 65(63-67); and group Zr2: 64(60-68), 85(80-91), and 75(70-81). The comparison between non-cemented and cemented stages in each group demonstrated a significant increase in the marginal gap values after cementation in all groups (p < .001), while the comparison between cemented and aged stages in each group showed a significant decrease in the marginal gap values in groups Al1, Al2, and Zr1 (p < .0001). This reduction was not significant for groups Ti1, Ti2, and Zr2 (p > .05).
CONCLUSION: The marginal accuracy of all tested restorations meets the requirements for clinical acceptance.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18241217     DOI: 10.1111/j.1708-8208.2007.00079.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  3 in total

1.  Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections.

Authors:  Hakimeh Siadat; Elaheh Beyabanaki; Niloufar Mousavi; Marzieh Alikhasi
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

2.  Effect of Abutment Geometry and Luting Agents on the Vertical Marginal Discrepancy of Cast Copings on Implant Abutments: An In Vitro Study.

Authors:  Jose Rosas; Frank Mayta-Tovalino; Violeta Malpartida-Carrillo; Arnaldo Munive Degregori; Roman Mendoza; Maria E Guerrero
Journal:  Int J Dent       Date:  2021-06-21

3.  Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques.

Authors:  Ying Zhou; Yong Li; Xiao Ma; Yiqing Huang; Jiawei Wang
Journal:  J Adv Prosthodont       Date:  2017-04-06       Impact factor: 1.904

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.