Literature DB >> 18238678

The impact of piezoelectric PVDF on medical ultrasound exposure measurements, standards, and regulations.

G R Harris1, R C Preston, A S Dereggi.   

Abstract

This paper describes the development of PVDF hydrophones for characterizing medical ultrasound fields. The polymer hydrophone approaches that have resulted from this work are discussed, with emphasis given to the spot-poled membrane design that has become the de facto reference device for these measurements. The various national and international standards and regulations that have followed from the successful use of PVDF hydrophones also are summarized. The works discussed encompass polymer-based hydrophones designed primarily for diagnostic and lithotripsy exposure measurements, both in water and in vivo. The advent of these hydrophones has made possible accurate and reliable measurements of exposure levels encountered in medical ultrasound and, thus, has allowed questions of ultrasound bioeffects and device safety to be addressed in a consistent and scientifically sound manner.

Entities:  

Year:  2000        PMID: 18238678     DOI: 10.1109/58.883521

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  Nonlinear Acoustics in Ultrasound Metrology and other Selected Applications.

Authors:  Peter A Lewin
Journal:  Phys Procedia       Date:  2010-01-01

2.  Wireless Wearable Ultrasound Sensor to Characterize Respiratory Behavior.

Authors:  Ang Chen; Rachel Diane Rhoades; Andrew Joshua Halton; Jayden Charles Booth; Xinhao Shi; Xiangli Bu; Ning Wu; Junseok Chae
Journal:  Methods Mol Biol       Date:  2022

3.  Characterization of a setup to test the impact of high-amplitude pressure waves on living cells.

Authors:  Mischa Schmidt; Ulf Kahlert; Johanna Wessolleck; Donata Maciaczyk; Benjamin Merkt; Jaroslaw Maciaczyk; Jens Osterholz; Guido Nikkhah; Martin O Steinhauser
Journal:  Sci Rep       Date:  2014-01-24       Impact factor: 4.379

4.  Ultra-Sensitive Strain Sensor Based on Flexible Poly(vinylidene fluoride) Piezoelectric Film.

Authors:  Kai Lu; Wen Huang; Junxiong Guo; Tianxun Gong; Xiongbang Wei; Bing-Wei Lu; Si-Yi Liu; Bin Yu
Journal:  Nanoscale Res Lett       Date:  2018-03-14       Impact factor: 4.703

5.  Characterization of Ultrasonic Bubble Clouds in A Liquid Metal by Synchrotron X-ray High Speed Imaging and Statistical Analysis.

Authors:  Chuangnan Wang; Thomas Connolley; Iakovos Tzanakis; Dmitry Eskin; Jiawei Mi
Journal:  Materials (Basel)       Date:  2019-12-20       Impact factor: 3.623

  5 in total