Interpolation methods for time-delay estimation using cross-correlation method for blood velocity measurement.

X Lai1, H Torp.   

Abstract

The cross-correlation method (CCM) for blood flow velocity measurement using Doppler ultrasound is based on time delay estimation of echoes from pulse-to-pulse. The sampling frequency of the received signal is usually kept as low as possible in order to reduce computational complexity, and the peak in the correlation function is found by interpolating the correlation function. The parabolic-fit interpolation method introduces a bias at low sampling rate to the ultrasound center frequency ratio. In this study, four different methods are suggested to improve the estimation accuracy: (1) Parabolic interpolation with bias-compensation, derived from a theoretical signal model. (2) Parabolic interpolation combined with linear filter interpolation of the correlation function. (3) Parabolic interpolation to the complex correlation function envelope. (4) Matched filter interpolation applied to the correlation function. The new interpolation methods are analyzed both by computer simulated signals and RF-signals recorded from a patient with time delay larger than 1/f(0), where f(0) is the center frequency. The simulation results show that these methods are more accurate than the parabolic-fit method. From the simulation, the worst estimation accuracy is about 1.25% of 1/f(0) for the parabolic-fit interpolation, and it is improved by the above methods to less than 0.5% of 1/f(0) when the sampling rate is 10 MHz, the center frequency is 2.5 MHz and the bandwidth is 1 MHz. This improvement also can be observed in the experimental data. Furthermore, the matched filter interpolation gives the best performance when signal-to-noise ratio (SNR) is low. This is verified both by simulation and experimentation.

Entities:  

Year:  1999        PMID: 18238424     DOI: 10.1109/58.753016

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  3 in total

1.  External vibration multi-directional ultrasound shearwave elastography (EVMUSE): application in liver fibrosis staging.

Authors:  Heng Zhao; Pengfei Song; Duane D Meixner; Randall R Kinnick; Matthew R Callstrom; William Sanchez; Matthew W Urban; Armando Manduca; James F Greenleaf; Shigao Chen
Journal:  IEEE Trans Med Imaging       Date:  2014-07-09       Impact factor: 10.048

2.  3-D phantom and in vivo cardiac speckle tracking using a matrix array and raw echo data.

Authors:  Brett Byram; Greg Holley; Doug Giannantonio; Gregg Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-04       Impact factor: 2.725

3.  An approach to unbiased subsample interpolation for motion tracking.

Authors:  Matthew M McCormick; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.