Literature DB >> 18237953

Data redundancy and reduced-scan reconstruction in reflectivity tomography.

Xiaochuan Pan1, Yu Zou, M A Anastasio.   

Abstract

In reflectivity tomography, conventional reconstruction approaches require that measurements be acquired at view angles that span a full angular range of 2pi. It is often, however, advantageous to reduce the angular range over which measurements are acquired, in order, for example, to minimize artifacts due to movements of the imaged object. Moreover, in certain situations, it may not be experimentally possible to collect data over a 2pi angular range. We investigate the problem of reconstructing images from reduced-scan data in reflectivity tomography. By exploiting symmetries in the data function of reflectivity tomography, we demonstrate heuristically that an image function can be uniquely specified by reduced-scan data that correspond to measurements taken over an angular interval (possibly disjoint) that spans at least pi radians. We also identify sufficient conditions that permit for a stable reconstruction of image boundaries from reduced-scan data. Numerical results in computer-simulation studies indicate that images can be reconstructed accurately from reduced-scan data.

Year:  2003        PMID: 18237953     DOI: 10.1109/TIP.2003.814244

Source DB:  PubMed          Journal:  IEEE Trans Image Process        ISSN: 1057-7149            Impact factor:   10.856


  5 in total

1.  Curved array photoacoustic tomographic system for small animal imaging.

Authors:  John Gamelin; Andres Aguirre; Anastasios Maurudis; Fei Huang; Diego Castillo; Lihong V Wang; Quing Zhu
Journal:  J Biomed Opt       Date:  2008 Mar-Apr       Impact factor: 3.170

2.  Fast, limited-data photoacoustic imaging for multiplexed systems using a frequency-domain estimation technique.

Authors:  John K Gamelin; Andres Aguirre; Quing Zhu
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

3.  Multi-excitation magnetoacoustic tomography with magnetic induction for bioimpedance imaging.

Authors:  Xu Li; Bin He
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

4.  Weight factors for limited angle photoacoustic tomography.

Authors:  G Paltauf; R Nuster; P Burgholzer
Journal:  Phys Med Biol       Date:  2009-05-08       Impact factor: 3.609

5.  High-speed three-dimensional photoacoustic computed tomography for preclinical research and clinical translation.

Authors:  Li Lin; Peng Hu; Xin Tong; Shuai Na; Rui Cao; Xiaoyun Yuan; David C Garrett; Junhui Shi; Konstantin Maslov; Lihong V Wang
Journal:  Nat Commun       Date:  2021-02-09       Impact factor: 14.919

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.