Literature DB >> 18237708

Cyclic load testing and ultimate failure strength of biodegradable glenoid anchors.

F Alan Barber1, David A Coons, Michell Ruiz-Suarez.   

Abstract

PURPOSE: The purpose of this study was to compare biodegradable glenoid suture anchors by cyclic loading and load to failure testing.
METHODS: Seven different suture anchors (BioKnotless and Lupine Loop [DePuy-Mitek, Norwood, MA]; BioPushLock, BioSutureTak, and BioFasTak [Arthrex Corp, Naples, FL]; BioAnchor [Conmed Linvatec, Largo FL]; and BioRaptor [Smith & Nephew, Andover, MA]) were tested in 8 matched pairs of human cadaver fresh-frozen glenoids. The anchors were inserted in rotation into different glenoid rim positions. Sutures attached to the anchors were fixed to an Instron 8871 machine (Instron, Canton, MA) and cyclic loading and destructive testing were performed. The cyclic displacement at 100 and 500 cycles, stiffness, ultimate failure strength, and mode of failure were determined.
RESULTS: No statistical difference was found in the ultimate failure load for any of these anchors. The Lupine Loop and BioAnchor had greater 100 cycle and 500 cycle mean displacements than the BioPushLock and BioSutureTak. The Lupine Loop also had greater 100 cycle and 500 cycle mean displacement than the BioFasTak (P < .05). The BioAnchor had greater mean 500 cyclic displacement than the BioFasTak (P < .05). Mean BioSutureTak stiffness was greater than the Lupine Loop, BioAnchor, BioKnotless, and BioRaptor (P < .05).
CONCLUSIONS: No differences in ultimate failure strength after cyclic loading were found in these seven biodegradable glenoid anchors (BioKnotless, Lupine Loop, BioPushLock, BioSutureTak, BioFasTak, BioAnchor, and BioRaptor). Most displacement occurred in the first 100 cycles. Displacement at 500 cycles was greater for the Lupine Loop and the BioAnchor than the BioPushLock, BioSutureTak, and BioFasTak. Failure was principally by the anchor pulling out of bone except for the BioSutureTak, which also failed by the suture loop eyelet pulling out of the anchor body, and the BioPushLock which failed by the suture slipping past anchor. CLINICAL RELEVANCE: Biodegradable glenoid anchors did not show statistical difference in ultimate failure load after cyclic loading.

Entities:  

Mesh:

Year:  2007        PMID: 18237708     DOI: 10.1016/j.arthro.2007.08.011

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  11 in total

1.  Comparison between metal and biodegradable suture anchors in the arthroscopic treatment of traumatic anterior shoulder instability: a prospective randomized study.

Authors:  Giuseppe Milano; Andrea Grasso; Domenico A Santagada; Maristella F Saccomanno; Laura Deriu; Carlo Fabbriciani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-07-17       Impact factor: 4.342

2.  Biomechanical evaluation of knotless anterior and posterior Bankart repairs.

Authors:  Frank Martetschläger; Max P Michalski; Kyle S Jansson; Coen A Wijdicks; Peter J Millett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-05       Impact factor: 4.342

3.  A simple surgical technique for subpectoral biceps tenodesis using a double-loaded suture anchor.

Authors:  William F Scully; David J Wilson; Jason A Grassbaugh; Joanna G Branstetter; Bryant G Marchant; Edward D Arrington
Journal:  Arthrosc Tech       Date:  2013-05-23

Review 4.  [Complications related to implants in arthroscopic shoulder surgery].

Authors:  O Lorbach; P Wilmes; P Brogard; R Seil
Journal:  Orthopade       Date:  2008-11       Impact factor: 1.087

5.  Restoring the labral height for treatment of Bankart lesions: a comparison of suture anchor constructs.

Authors:  Mark A Slabaugh; Nicole A Friel; Vincent M Wang; Brian J Cole
Journal:  Arthroscopy       Date:  2010-03-04       Impact factor: 4.772

6.  MRI graduation of osseous reaction and drill hole consolidation after arthroscopic Bankart repair with PLLA anchors and the clinical relevance.

Authors:  T Stein; A P Mehling; M Ulmer; C Reck; T Efe; R Hoffmann; A Jäger; F Welsch
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-02       Impact factor: 4.342

7.  Repair integrity and functional outcomes of arthroscopic repair in chronic anterior shoulder instability: single-loaded versus double-loaded single-row repair.

Authors:  Woo-Yong Lee; Hyun-Dae Shin; Kyung-Cheon Kim; Soo-Min Cha; Yoo-Sun Jeon; Jae-Hwang Song
Journal:  Arch Orthop Trauma Surg       Date:  2020-11-01       Impact factor: 3.067

8.  Stapled fascial suture: ex vivo modeling and clinical implications.

Authors:  Enrico Lauro; Ilaria Corridori; Lorenzo Luciani; Alberto Di Leo; Alberto Sartori; Jacopo Andreuccetti; Diletta Trojan; Giovanni Scudo; Antonella Motta; Nicola M Pugno
Journal:  Surg Endosc       Date:  2022-05-16       Impact factor: 4.584

9.  Biomechanical Comparison of a First- and a Second-Generation All-Soft Suture Glenoid Anchor.

Authors:  John Erickson; Frank Chiarappa; Jonathan Haskel; Justin Rice; Adam Hyatt; James Monica; Aman Dhawan
Journal:  Orthop J Sports Med       Date:  2017-07-20

10.  Anatomic Knot Suture Anchor Versus Knotless Suture Anchor Technique for Anterior Talofibular Ligament Repair: A Biomechanical Comparison.

Authors:  Hong Li; Hanlin Xu; Yinghui Hua; Wenbo Chen; Hongyun Li; Shiyi Chen
Journal:  Orthop J Sports Med       Date:  2020-01-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.